Cleaning And Maintenance - Futurelight SC-380 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Rotating gobos
- 9 metal gobos rotating in both directions at different speeds
- Gobo indexing
- Rotating gobo-wheel cont. rotation
- Outside diameter 16 mm, image diameter 13 mm
Strobe
- Strobe effect with variable speed (1 - 8 flashes per second)
Motor
- 6 high quality stepping-motors controlled by microprocessors
Electronics
- Intelligent control panel with 3-digit LED display allowing: addressing PAN and TILT reverse, effect
calibration, reset of the unit and built-in test sequence running
- Digital serial input DMX-512
- 6 control-channels:
Channel 1: Horizontal mirror-movement (Pan)
Channel 2: Vertical mirror-movement (Tilt)
Channel 3: Colour-wheel
Channel 4: Rotating gobo-wheel
Channel 5: Rotating gobo index, rotating gobo rotation
Channel 6: Shutter, Strobe
Housing
- Easy access to lamp and main components thanks to large opening cover and the projector's modular
construction.
Temperatures
Maximum ambient temperature t
Maximum housing temperature t
Dimensions and weight
- L x W x H:
470 x 280 x 160 mm
- Weight:
11 kg
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
4) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
: 45° C
a
(steady state): 80° C
B

Cleaning and maintenance

DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
29

Publicité

Table des Matières
loading

Table des Matières