3. Terminal Connection Method
Pay attention to the input wiring. If it is connected to wrong terminal, the power supply will be damaged.
Input must be off when making connections.
Connect terminal of input connector and mounting hole to protective earth of the equipment.
Output current of each terminal pin must be less than 5A.
The output load line and input line shall be separated to improve noise sensitivity.
Do not apply stress to PCB, when connecting or removing connector.
Do not apply stress to other components, when connecting or removing connector.
Use input/output connector (housing) specified by the table below.
Use recommended crimping tool. Connector is not included with this product. (Refer to the following)
Input/Output Connector
Input ( CN1 )
Output ( CN51 )
Hand Crimping Tool : YC-160R (J.S.T.)
4
E xplanation of Function and Precautions
. . . .
4-1. Input Voltage Range
Input voltage range is single phase 85-265VAC (47-63Hz) or 120-370VDC. Input voltage, which is out of specification, might lead unit
damage. For cases where conformance to various safeties required, input voltage range will be 100-240VAC (50-60Hz).
Connector
Housing
B3P5-VH(LF)(SN)
VHR-5N
VHR-8N
B 8 P -VH(LF)(SN)
C U T75
Terminal Pin
Maker
SVH-21T-P1.1
J.S.T.
BVH-21T-P1.1
- 3 -
TDK-Lambda
CUT75
Instruction Manual