LED
-V
+V
FG
L
N
9-M3.5
L : AC Input terminal Live line (Fuse in line.)
N : AC Input terminal Neutral line
FG: Frame Ground (Protective Bonding)
Vadj: Output voltage adjust trimmer. The output voltage rises when a trimmer is turned clockwise.
+V : + Output Terminal
-V : - Output Terminal
LED: Output monitoring indicator (Green color)
Pay attention to the input wiring. If it is connected to wrong terminal, the power supply will be damaged.
Input must be off when making connections.
Connect FG terminal of input connector to protective earth of the equipment.
The output load line and input line shall be separated to improve noise sensitivity.
Output current of each terminal pin of CUS250LD Series must be less than 2 A.
LOAD
4-1. Input Voltage Range
Input voltage range is single phase 85-265VAC (47-63Hz). Never operate the unit out of the specified input voltage range to avoid unit
failure.
For cases where conformance to various safety requirement, input voltage range will be 100-240VAC (50 60Hz).
Vadj
- 1 -
TDK-Lambda
CUS250LD Series
Instruction Manual