Transmission Modes - ADEUNIS TEMP V3 LoRaWAN 863 Guide Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TEMP V3 LoRaWAN 863-870 - Guide utilisateur / User guide version V3.0.0

2.2. Transmission modes

The product allows to measure temperature on 2 probes or 1 probes only, to save the information and to send it according to 3 modes of emis-
sion.
FR
The periodical transmission allows the
temperature to be collected according
Definition
to a specified period of time, to be
saved and sent on a regular basis for
analysis over time.
EN
I want to measure my temperature on
the 2 probes every 30 minutes. I want
Concrete case
to minimize the number of frame per
of usage
day and to optimize the autonomy so
I prefer to send the maximum of data
in each frame without loosing data.
Sampling period
= 900 (900s x2 =1800 seconds so 30
minutes)
Number of samples before
saving
= 1 (1 saving at each reading)
Number of saving before
Associated
transmission
configuration
= 12 (12 savings per frame)
• Probe 1 alarm (S330)
= 0 (alarm disabled)
• Probe 2 alarm (S340)
= 0 (alarm disabled)
In the user
Paragraph 2.1.5.01
guide
WARNING: the number of data per frame depends on the network used. Here the case is available on a LoRaWAN Network.
Transmission period = number of savings
Sampling
period =
(historisation) done between each transmission
10min
Sample/
Historisation
reading
Periodical transmission
(S321)
(S320)
(S301)
S301 = 12 x 1h = 12h
Over threshold transmission
The over threshold transmission enables
to read the temperature according to a
specified period of time but to send the
alarm frame only if a threshold is
over passed.
I want that the product send me an
alarm if the temperature is lower than
10°C on probe 1.
Sampling period
(S321)
= 300 (300s x2 =10 minutes)
Number of saving before
transmission
(S301)
= 0 (no periodical transmission)
• Alarm temperature on probe 1 (S330)
= 1 (low threshold)
• Low threshold on probe 1(S333)
= 100 (in tenth of °C)
• Low threshold hysteresis on probe 1
(S334)
= 50 (in tenth of °C) the alarm is raised
only if my temperature exceeds 15 °C.
Paragraph 2.1.5.02
Historisation period = number of samples
(readings) done between each saving
Transmission
Periodical and over threshold
transmission
Mix of the 2 modes to measure
temperature regularly in order to be
alerted if a threshold is over passed and
to save the information to make analysis
over time.
I want to know the temperature on the
2 probes along the day and be informed
if the temperature go under 10°C on
the probe 1. The product will send me a
frame twice a day with the temperature
measured each hour and an alarm if
the temperature is under 10°C on the
probe 1.
Sampling period
(S321)
= 300 (300s x2 =10 min)
Number of samples before
saving
(S320)
= 6 (6 x 10 min = 1h)
Number of saving before trans-
mission
(S301)
= 12 (12 X 1h = 12h)
• Alarm temperature on probe 1 (S330)
= 1 (low threshold)
• Low threshold on probe 1 (S333)
= 100 (in tenth of °C)
• Low threshold hysteresis on probe 1
(S334)
= 50 (in tenth of °C) the alarm is raised
only if my temperature exceeds 15 °C.
See here under explanation
S320 = 6 x 10min = 1h
Time
40 of 51