When at these lower temperatures the ignition procedure is not resulting in a
good burning fire the display will mention "Ont".
To start the fire put some "fire starter" or "fire lighters" in the fire bed.
Light the fire starter using a match and wait for 1 minute before starting the stove
using the "normal starting up procedure" as described in §D.1.1.1
When this is not leading to a good burning fire it is required that the installation
parameters of the stove will be changed by a professional. Contact a Zibro agreed
installer.
G
D.2 changing The ReqUiReD ROOM TeMPeRaTURe
1.
2. P ress P1 within 3 seconds to increase the required room temperature, display B
3. P ress P2 within 3 seconds to decrease the required room temperature, display
4. W hen display B displays the desired required room temperature: do not press
5.
The required temperature can be changed between minimum 06°C to maximum 41°C.
D.3 nORMaL sWiTching OFF
To switch off the stove keep P4 pressed, until "OFF" is displayed in Display A.
During the switching off phase the supply of wood pellets to the burning pot is
stopped, the room air circulation fan is switched off, the smoke extraction fan is
turned off after 20 minutes.
D.4 eMeRgency sWiTching OFF
In case of emergency: Never use water to stop the fire. Use a CO
fire extinguisher and / or call the fire brigade. In case of chimney fire also close the
chimney damper (if mounted).
D.5 changing The POWeR OUTPUT LeVeL OF The sTOVe
When the burner is in operation AND the required room temperature is not yet
achieved pressing P5 or P6 will respectively increase or decrease the power output
of the stove by changing the burning level. Display A will change and show the
corresponding power output level of the stove. See picture 4.
4
94
Do not use other fuel than the mentioned wood pellets. Other fuels such
as fore example - wood work scraps with glues and/or solvents, - waste
wood in general, - cardboard, - liquid fuel, - alcohol, - petrol, - gasoline, -
waste materials or rubbish, etc are forbidden.
Press P3 once.
will show the changed required temperature.
B will show the changed required temperature.
any button anymore, wait for 3 seconds and the display will return to its nor-
mal operating mode.
Changing the required room temperature is now completed.
(carbon dioxide)
2
Picture 4