Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Continual operation
By operating the right switch on the back of the device the continual bubble emission starts.
Remote control operation
Connect the remote control with the Remote Control-socket. Switch on the left switch on the back of the
device.
By operating the button on the remote control the bubble emission starts.
ATTENTION: The remote control feature can only operate when the left switch has been turned on
and the right switch has been turned off.
CLEANING AND MAINTENANCE
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no servicable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers.
Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
International
L
N
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!