USE
following controls luminous:
A = LIGHT
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III
F = AUTOMATIC STOP TIMER - 15 minutes (*)
A
B
C
D
E
F
By pressing key F for two seconds (with
the hood switched off ) the "clean air"
function is activated. This function switch-
es the appliance on for ten minutes every
hour at the first speed. As soon as this
function is activated the motor starts up
at the first speed for ten minutes. During this time key F and key C must flash at the same
time. After ten minutes the motor switches off and the LED of key F remains switched on
with a fixed light until the motor starts up again at the first speed after fifty minutes and
keys F and C start to flash again for ten minutes and so on. By pressing any key for the
exclusion of the hood light the hood will return immediately to its normal functioning
(e.g. if key D is pressed the "clean air" function is deactivated and the motor moves to
the 2nd speed straight away. By pressing key B the function is deactivated).
(*) The "automatic stop timer" delays stopping of the hood, which will continue func-
tioning for 15 minutes at the operating speed set at the time this function is activated.
- When button A flashes at a frequency of 2 seconds, the grease filters must be cleaned.
- When button A flashes at a frequency of 0.5 seconds, the carbon filters must be replaced.
After the clean filter has been replaced, the electronic memory must be reset by pressing
button A for approximately 5 seconds, until the light on the button stops flashing.
- 20 -