PLACING THE MACHINE IN SERVICE
LUBRIFICATION
Always use of an air line lubricator with these machine. We recommended the
following Filter-Lubricator-Regulator Unit: FACOM N.580.
Every eight hours' operation, if a lubricator is not used on the compressed air
network, inject 1/2 to 1cm
through the machine's inlet connection.
3
1
5
Model
Milling cutter
mm
V.781F
Ø 8
Model
Free speed
rpm
V.781F
1800
* k = measurement uncertainty in dB
WE, FACOM S.A.S., 6/8 RUE GUSTAVE EIFFEL - BP 99 - 91 423 MORANGIS CEDEX FRANCE, DECLARE UNDER OUR OWN RESPONSIBILITY THAT THE
PRODUCT V.781F – FACOM PNEUMATIC SPOT WELD REMOVER
- IS IN CONFORMITY WITH THE «MACHINERY» DIRECTIVE 2006/42/CE
- AND IS IN CONFORMITY WITH THE PROVISIONS OF THE HARMONISED EUROPEAN STANDARD EN 11148-3:2012
ISO 12100-2010
ISO 15744:2008
ISO 8662-1
NU-V.781F_0915.indd 6
2 2
2
4,5 mm / 50µm
6
Pressure dB(A)
k*
86,4
3
Air consumption
Working
pressure
l/min
110
** k = measurement uncertainty in m/s²
CE DECLARATION OF CONFORMITY
EMERGENCY
GATE VALVE
3
4 4
4
7
Noise level
Power dB(A)
Pressure dB(A)
k*
97,4
3
110
Weight
Dimensions
bar
kg
6,2
2,1
293x149x54
8 8 8
Vibrations level
m/s
2
k*
k**
3
< 2,5
0,54
mm
20.01.2010
F
ACOM QUALITY MANAGER
9/24/2015 11:29:13 AM