3.1.3 ON/OFF switch
Two-pole ON/OFF switch with turn-on inhibit and locking.
3.1.4 Protection of the machine
• Starting current limitation the electronically controlled soft starting provides for smooth starting
of the machine. Due to the low machine starting current a 16A fuse is adequate.
• Temperature-dependent overload protection for protection against overheating, when a critical
temperature is reached the electronic safety feature switches into the cool down mode. Then the
machine continues to run at approx.: 3,200 rpm and the electronic constant speed control is
deactivated. After a cool-down time of approx. 10 - 20 sec. the machine is again ready for
operation. Turn the machine off and back on again to activate the electronic constant speed
control. When the machine is at operating temperature the temperature-dependent overload
protection reacts correspondingly earlier time.
• Overvoltage/restarting protection
On short-time outage of the power voltage (pulled power connector, unstable power voltage etc.)
the machine will stop. On recovery of the power voltage the machine has to be turned off and back
on again. The machine is then ready for operation.

3.2 Beveling tool

Use only Beveling tools whose admissible maximum speed is equal to or higher than the no load
speed of the machine.
Use only clean tools!
3.2.1 Changing a Bevel Head
• Disconnect from power supply.
• Lock spindle with the locking ring (pic 2) by turning the ring and pull it backwards.
• Use the Hex wrench (4mm) to unscrew the guide bearing.
• Take the bevel head of.
3.2.2 Fitting a Bevel Head
• Before fitting the Bevel head clean the surface of the adapter and Bevel Head.
• Check the guide bearing, it should run smoothly, a guide bearing that doesn't run smoothly will
damage the Bevel head and can lead to a broken Bevel Head.
• Place Bevel Head on the adapter, the pin on the adapter should easily fit into the pinhole in the
Bevel Head.
• Lock spindle with the locking ring (pic 2) by turning the ring and pull it backwards.
• Use the Hex wrench (4mm) to tighten the guide bearing.
• Check if the Bevel head runs smoothly and true, not true running Bevel heads must be replaced
immediately.
Check Bevel tool before use. The Bevel head must be correctly mounted and must rotate freely.
Perform a trial run a minimum over a period of 30 seconds without load. Do not use Bevel Heads
which are damaged, which do not run true or which vibrate!