CUS100ME Handbook
Mounting
Customer fixings, at locations A, B, C and D, must not bridge Creepage and Clearance distance spacing.
Ensure the following creepages and clearances are maintained for customer fixing points A, B, C and D.
Based on IEC/EN/UL60950-1
At 3000m operation, 2.3mm Clearance, 2.5mm creepage
At 4000m operation, 2.6mm Clearance, 2.6mm creepage
At 5000m operation, 3.0mm Clearance, 3.0mm creepage
IEC/EN/UL60601-1
At 3000m operation, 2.5mm Clearance, 4mm creepage
At 4000m operation, 2.9mm Clearance, 4mm creepage
At 5000m operation, 3.3mm Clearance, 4mm creepage
IEC/EN/UL62368-1
At 3000m operation, 1.8mm Clearance, 2.4mm creepage
At 4000m operation, 2.0mm Clearance, 2.4mm creepage
At 5000m operation, 2.3mm Clearance, 2.4mm creepage
All four mounting points (A, B, C, D) should be used to support the unit.