has more capacity than 18 gauge. An undersized cord will cause a
drop in line voltage resulting in loss of power and overheating. When
using more than one extension to make up the total length, be sure
each individual extension contains at least the minimum wire size.
The following table shows the correct size to use depending on cord
length and nameplate ampere rating. If in doubt, use the next heavier
gauge. The lower the gauge number, the heavier the cord.
Minimum Gauge for Cord Sets
Volts
120 V
25
Ampere
Rating
(7.6)
240 V
50
(15.2)
More
Not
More
Than
Than
0
6
18
6
10
18
10
12
16
12
16
14
• The label on your tool may include the following symbols. The
symbols and their definitions are as follows:
V ................... volts
Hz ................. hertz
min ............... minutes
or DC ... direct current
Total Length of Cord
in Feet (meters)
50
100
150
(15.2)
(30.5)
(45.7)
100
200
300
(30.5)
(61.0)
(91.4)
AWG
16
16
14
16
14
12
16
14
12
12
Not Recommended
A ......................amperes
W .....................watts
or AC ..........alternating
........................current
................. Class I Construction
.....................
(grounded)
................. Class II Construction ........................current
.....................
(double insulated)
.../min .......... per minute
BPM ............. beats per minute
IPM ............... impacts per minute
RPM ............. revolutions per
.....................
minute
sfpm ............. surface feet
.....................
per minute
SPM ............. strokes per minute
.................wear eye protection .........................radiation
.................wear respiratory
.....................protection
SAVE THESE INSTRUCTIONS
FOR FUTURE USE
COMPONENTS (FIG. 1–4)
WARNING: Never modify the corded power supply or any
part of it. Damage or personal injury could result.
A. AC connector
B. Release button
C. Cord clip
D. Dust cover (Fig. 2)
2
or AC/DC ...alternating
........................or direct
n o ....................no load
........................speed
n ......................rated
........................speed
.....................earthing
........................terminal
.....................safety alert
........................symbol
....................visible
.....................wear hearing
.........................protection
E. Tool's corded power supply
receptacle (Fig. 2)
F. Dust cover holder (Fig. 3)
G. Tool's cord holder (Fig. 4)