Dépannage Et Conseils - Baumer PosCon OXH7 Mode D'emploi

Masquer les pouces Voir aussi pour PosCon OXH7:
Table des Matières

Publicité

5.6 Dépannage et conseils
Error
No function
Green LED flashes
Red LED lights up
Sensor does not provide the
expected measuring results
The sensor does not take
account of all objects within the
field of view
Unreliable measurement value:
The measurement value jumps
back and forth
Transmitting laser light is dim
Incorrect measurement values
A communication error occurs
during changing the IP address
No tool status message during
an error
fr_BA_PosCon_OXH7_TCP_IP.docx
vendredi 23 novembre 2018 16:59:22/stke V1.1 ANW_81184815
Error correction
Check connection. Power supply 15...28 VDC on pin 2 (+Vs,
brown) and pin 7 (GND, blue)
Short circuit on switching outputs. Check connection
Object outside field of view (near, far, or to the side)
Amplitude of the received signal is insufficient (e.g., in case of
soiling)
Check inclination angle and work in Flex Mount mode if required
(teach the new reference surface)
The object is not in the measuring range
Bright object, avoid direct reflexes from the transmitter to the
receiver
Enlarge field of view. The field of view was possibly limited; see
Section "FIELD OF VIEW"
The red visible laser beam does not represent the maximum field
of view. If the object is at the edge of this beam it could be outside
the measuring range
Move object. The object is outside the field of view vertically or is
in the blind region of the sensor
The object is not in the measuring range
Avoid bright object
Avoid very dark object
Too much ambient light
Check measurement mode setting (MEASUREMENT MODE)
Sync-In input is on High--> set to Low
This is probably due to a malfunction caused by ambient light. Attempts
should be made to reduce the ambient light
If the IP address is changed, it must be reconnected to the sensor
A tool status message only states that the communication with the sensor
that was initiated by the call was successful. If there are problems, for
example when teaching with Flex Mount, this is returned by the sensor as
an error code
91/99
Baumer Electric AG
Frauenfeld, Suisse

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

11185166

Table des Matières