13. Switching on and turning off
Press and hold down the ON/STAND-BY key for 2 sec: the on/stand-by LED will switch off/on
13.1 Setpoint setting
press and release the SET key: the compressor LED will flash
press and release the UP or DOWN key within 15 sec
press and release the SET key or do not operate for 15 sec: the compressor LED will switch off
and then the instrument will exit the procedure.
To exit the procedure before the operation is complete:do not operate for 15 sec (any changes will be saved)
13.2 Manual defrosting
To activate manual defrost it is sufficient to hold the DEFROSTING key for 4 sec.
13.3 Locking/unlocking the keyboard
To lock the keyboard:
make sure that no other procedure is in progress
press and hold down the DOWN and ON/STAND-BY keys for 1 sec: the display will show the message
"Loc" for 1 sec.
To unlock the keyboard:
press and hold down the DOWN and ON/STAND-BY keys for 1 sec: the display will show the message
"UnL" for 1 sec.
13.4 Silencing the Buzzer (If available)
Press a key (the first pressing of the key will not cause the effect associated with that key)
ERRORS
CODE
Pr1
Pr2
When the problem that caused the alarm disappears, the instrument returns to normal operation
ALARMS
CODE
Id
dFd
When the problem that caused the alarm disappears, the instrument returns to normal function,
except for dFd alarm which needs to push a button
FAILURE
Cell probe
error
Evaporator
probe error
Door microswitch input alarm
(only for uprights)
Defrosting alarm switched off
because maximum time has
been reached
FAILURE SOLUTION
Verify that the probe is intact
Check the cell temperature
Verify that the probe is intact
Check the cell temperature
Close the door
Contact Servicing
FAILURE SOLUTION
15