Startup
Installing the CTI-/audio-link
-- On the T3 Comfort, close the display cover.
-- Turn the T3-telephone over. On the underside, there are
one or two slots for inserting Tenovis links. If both slots are
free, always use the inner slot 1 for the CTI-/audio-link.
-- Disconnect ISDN-connection lead and all external network
devices (telephone disconnected from power supply).
-- Insert the catches on the link (on the tip of the wedge
shape) into the openings provided on the base of the
telephone (a).
-- Carefully press the link downwards into the slot (b).
-- Re-connect the telephone with the ISDN-connection lead
and start it up.
-- After an automatic test routine, the telephone is once
again ready to use and detects the inserted link.
On the I33/I55, the Comfort or Classic will also show a
message confirming which type of link has been started
up in which slot.