Capacitance (Autoranging)
4 ηF
Range
40 ηF
400 ηF
4 µF
40 µF
400 µF
4 mF
40 mF
Frequency (Autoranging)
Range
4 kHz
Sensitivity .....................................>5 V RMS minimum
Temperature
Range
-40°C to +1000°C 1°C
-40°F to +1832°F 1°F
Diode Test
Range
0.3 mA Typical
Open Circuit Voltage .....................1.5 V DC
Audible Threshold .........................< 35 Ω
Audible Continuity
Test Current ..................................< 1.0 mA
Standard Equipment
The RIDGID
®
micro CM-100 Digital Clamp Meter comes with the following items:
• micro CM-100 Digital Clamp Meter
• Test Leads with Covers, Black and Red
• K Type Adapter and Temperature Probe
Figure 1 – micro CM-100 Digital Clamp Meter
Figure 2 – Back of micro CM-100 Digital Clamp Meter
6
micro CM-100 Digital Clamp Meter
0.001 ηF
Resolution
0.01 ηF
0.1 ηF
0.001 µF
0.01 µF
0.1 µF
0.001 mF
0.01 mF
Resolution
0.001 kHz
Resolution
Resolution
1 mV
Accuracy
±5.0% of Reading ± 30 Digits
±5.0% of Reading ± 20 Digits
±3.0% of Reading ± 5 Digits
±4.0% of Reading ± 10 Digits
±4.5% of Reading ± 10 Digits
±5.0% of Reading ± 10 Digits
Accuracy
±1.5% of Reading ± 2 Digits
Accuracy
±2.5% of Reading ± 3°C
±2.5% of Reading ± 5°F
Accuracy
±10% of Reading ± 5 Digits
• User Manual and Instruction CD
• Carrying Case
Warning
Label