2. TECHNICAL SPECIFICATIONS
2.1 Technical data for the swimming pool heat pump unit
Model
Heating capacity*
Electrical power rating *
Operating current *
Electrical connection
Fuse rating aM
D-curve circuit breaker
Number of compressors
Type of compressor
Number of fans
Fan power
Fan rotation speed
Fan direction
Acoustic power **
Sound pressure level
(at 10 m)
Hydraulic connection
Water flow rate
Water pressure drop (max)
Unit net dimensions (L/W/H)
Unit net weight
* Value +/- 5% in the following conditions: Outside temperature = 24°C / RH=62% / Water inlet temperature 26°C / Water outlet
temperature 28°C.
** Measurements according to EN 12102: 2013 and EN ISO 3744: 2010
2
ECOPAC
81502
kW
5,5
kW
1,19
A
5,33
V
230 V
Ph/Hz
1 / 50Hz
A
8 aM
A
8 D
1
Rotary
1
W
50
RPM
770
Horizontal
Lw dB(A)
66,7
dB(A)
38,2
mm
50
/h
2,3
m
3
kPa
1,0
mm
864/540/420
kg
46
81512
81522
8
10,6
1,70
2,37
7,54
11,84
230 V
230 V
1 / 50Hz
1 / 50Hz
10 aM
16 aM
10 D
16 D
1
1
Rotary
Rotary
1
1
120
120
850
850
Horizontal
Horizontal
69,2
71,2
40,7
42,7
50
50
3,4
4,5
1,3
4,0
1004/648/460
1004/648/460
59
66
81542
14,4
3,18
16,16
230 V
1 / 50Hz
20 aM
20 D
1
Scroll
1
120
850
Horizontal
70,6
42,1
50
6,0
6,8
1114/867/490
101