The unit doesn't
turn on .
If the problem cannot be resolved, or if you think something is still wrong with the unit, disconnect
●
the plug, reconnect after 30 seconds and operate it again.
Inside lid may turn yellow, but operation will not be affected.
●
"Clickety-clack" sound caused when open and close the lid is the sound caused by the valve
●
swing to prevent the hot water run off.
Outside body becomes 113°F(45°C) while warm keep if the room temperature is high.
●
The indicator lights flash
alternately and displays
.
Replacement of Parts
Rubber gasket set
Replace gaskets if they crack, lose their pliancy
or, for any other reasons which allow steam to
escape from between the container and the lid.
Remove lid, unscrew 3 tapping screws and
remove the lid cover.
Exchange the gaskets and then place the lid
cover back and secure with the tapping screws.
You poured in water directly from a tap.
●
You put the unit on the sink.
●
You turned the unit upside down with
●
its bottom wet.
You washed the unit in water.
●
This is a malfunction of the sensor. Contact the retailer where you
●
purchased the unit.
Lid cover
Set gaskets
If the electric components
●
get wet, the unit must
be repaired. Contact the
store where you purchased
the unit for repair.
Mesh filter
Replace the filter if foreign materials which
clog the filter cannot be removed even after
you scrub with a cleaning brush, etc.
Consumable parts are available from an
authorized dealer.
Part name
Rubber gasket set
Mesh filter
Part No.
APH65-613-0S
APB97-480-0U
23