Reaction Times Of The Co Alarm - Olymp KM 210 Mode D'emploi

Détecteur de co
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Reaction Times of the CO Alarm

The following table indicates the reaction times of the CO
alarm according to the levels of carbon monoxide�
Take each alarm seriously and follow the
instructions in Section In the Event of an
Alarm on Page 26�
Concentration*
Up to 50 ppm
Up to 100 ppm
Up to 300 ppm
From 300 ppm
* The concentration indicates the levels of carbon monox-
ide in the ambient air in ppm (parts per million).
Time Until CO Alarm is Triggered
Approx� 2 hours
Approx� 1 to 1�5 hours
Approx� 10 to 40 minutes
Max� 3 minutes
41

Publicité

Table des Matières
loading

Table des Matières