Mounting and Installation
Devices are to be connected under dead-voltage condition. Devices must
only be connected to safety extra-low voltage. Consequential damages
caused by a fault in this device are excluded from warranty or liability.
Installation of these devices must only be realized by authorized qualified
personnel. The technical data and connecting conditions shown on the
device labels and in the mounting and operating instructions delivered
together with the device are exclusively valid. Deviations from the cata-
logue representation are not explicitly mentioned and are possible in
terms of technical progress and continuous improvement of our pro-
ducts. In case of any modifications made by the user, all warranty claims
are forfeited. Operating this device close to other devices that do not
comply with EMC directives may influence functionality. This device must
not be used for monitoring applications, which solely serve the purpose
of protecting persons against hazards or injury, or as an EMERGENCY
STOP switch for systems or machinery, or for any other similar safety-
relevant purposes.
Dimensions of enclosures or enclosure accessories may show slight
tolerances on the specifications provided in these instructions.
Modifications of these records are not permitted.
In case of a complaint, only complete devices returned in original pack-
ing will be accepted.
Our "General Terms and Conditions for Business" together with the
"General Conditions for the Supply of Products and Services of the
Electrical and Electronics Industry" (ZVEI conditions) including supple-
mentary clause "Extended Retention of Title" apply as the exclusive
terms and conditions".
Notes regarding mechanical mounting and attachment:
Mounting shall take place while observing all relevant regulations and
standards applicable for the place of measurement (e.g. such as welding
instructions, etc.). Particularly the following shall be regarded:
– VDE ⁄ VDI directive technical temperature measurements, measure-
ment set - up for temperature measurements.
– The EMC directives must be adhered to.
– It is imperative to avoid parallel laying of current-carrying lines.
– We recommend to use shielded cables with the shielding being
attached at one side to the DDC ⁄ PLC.
G
General notes
Our "General Terms and Conditions for Business" together with the "General Conditions for the Supply of Products and Services of the Electrical
and Electronics Industry" (ZVEI conditions) including supplementary clause "Extended Retention of Title" apply as the exclusive terms and conditions.
In additionIn addition, the following points are to be observed:
– These instructions must be read before installation and putting in operation and all notes provided therein are to be regarded!
– Devices must only be connected to safety extra-low voltage and under dead-voltage condition. To avoid damages and errors the device
(e.g. by voltage induction) shielded cables are to be used, laying parallel with current-carrying lines is to be avoided, and EMC directives are to
be observed.
– This device shall only be used for its intended purpose. Respective safety regulations issued by the VDE, the states, their control authorities,
the TÜV and the local energy supply company must be observed. The purchaser has to adhere to the building and safety regulations and has to
prevent perils of any kind.
– No warranties or liabilities will be assumed for defects and damages arising from improper use of this device.
– Consequential damages caused by a fault in this device are excluded from warranty or liability.
– These devices must be installed by authorised specialists only.
– The technical data and connecting conditions of the mounting and operating instructions delivered together with the device are exclusively
valid. Deviations from the catalogue representation are not explicitly mentioned and are possible in terms of technical progress and continuous
improvement of our products.
– In case of any modifications made by the user, all warranty claims are forfeited.
– This device must not be installed close to heat sources (e.g. radiators) or be exposed to their heat flow. Direct sun irradiation or heat
irradiation by similar sources (powerful lamps, halogen spotlights) must absolutely be avoided.
– Operating this device close to other devices that do not comply with EMC directives may influence functionality.
– This device must not be used for monitoring applications, which solely serve the purpose of protecting persons against hazards or injury,
or as an EMERGENCY STOP switch for systems or machinery, or for any other similar safety-relevant purposes.
– Dimensions of enclosures or enclosure accessories may show slight tolerances on the specifications provided in these instructions.
– Modifications of these records are not permitted.
– In case of a complaint, only complete devices returned in original packing will be accepted.
These instructions must be read before installation and putting in operation and all notes provided therein are to be regarded!
Before mounting, make sure that the existing thermometer's technical
parameters comply with the actual conditions at the place of utilization,
in particular in respect of:
– Measuring range
– Permissible maximum pressure, flow velocity
– Oscillations, vibrations, shocks are to be avoided (< 0.5 g)
CONNECTING CONDITIONS
Output: 0 - 10 V
The output voltage follows linear to the temperature signal applied at
the input terminals and generates a proportional output signal of 0 - 10 V.
The voltage outputs are short-circuit proof against ground wire. Applying
voltage supply to the output terminals will destroy the device.
Output: 4 ... 20 mA
In case of the 4 ... 20 mA measuring transducer, display and evaluating
elements are connected in series in the current loop. The measuring
transducer thereby liWiths the flowing current in variance of the input
signal. 4 mA are for the measuring transducer's internal current con-
sumption. The apparent ohmic resistance can either be connected in the
plus or minus path of the measuring transducer. In case of an apparent
ohmic resistance in the plus path, power supply and resist.
SAFETY REGULATIONS
These devices shall only be used for their intended purpose. Respective
safety regulations issued by the VDE, the states, their control authori-
ties, the TÜV and the local energy supply company must be observed. The
buyer has to ensure adherence to the building and safety regulations and
has to avoid all dangers of any kind. We do not assume any warranty for
faults or damages arising or resulting from improper use of our equip-
ment or from non-observance of operating instructions. These instru-
ments must be installed by authorised specialists only!
Preferably shielded cables should be used in order to prevent damages ⁄
errors. It is imperative to avoid laying parallel with current-carrying
lines. EMC directives must be adhered to.