3 Precautions
Shut off all power going to header before attempting any wiring procedures.
5
Maintain a clean and safe environment when working in public areas.
5
Constantly be aware of pedestrian traffic around the door area.
5
Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions
5
by the door.
Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires
5
and cause damage to equipment or cable insulation.
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
5
4 Installation Notes
Handle the equipment with care. Damaging the mating surfaces of the magnet and armature plate may reduce locking efficiency.
5
The maglock mounts rigidly to the door frame. The armature plate mounts to the door with the hardware provided. This allows
5
the armature plate to pivot about its center to compensate for door wear and misalignment.
Template use must take place with the door in its normally closed position.
5
Add threadlocker to all screws before installing, and firmly tighten screws.
5
Install only for indoor, dry applications.
5
Installation and wiring must be performed in compliance with ANSI/NFPA70 regulations.
5
The Maglock shall be installed within the same room as other equipment and circuitry connecting to the Maglock (per UL 864).
5
5 Installation – Mechanical
TYPICAL INSTALLATION
Mounting Options
Filler
DOOR FRAME
DOOR
The rubber washer is designed to allow the armature plate to automatically adjust position for best mating position between the magnet and armature plate.
Page 2 of 4
Page 2 of 4
Page 2 of 4
DOOR FRAME
MAGNET
DOOR
ARMATURE PLATE
FILLER
MOUNTING PLATE
ARMATURE PLATE
DO NOT over-tighten the armature plate.
MOUNTING PLATE
L&Z bracket
DOOR FRAME
DOOR
Use the applicable mounting template.
See image of template below.
PLACE AGAINST HEADER
TEMPLATE
FOLD ON DOTTED LINE
PLACE AGAINST JAMB
PLACE AGAINST DOOR
OPPOSITE HINGES FOR
L.H.R. DOOR INSTALLATION
(11/16")
DRILL 16mm HOLE
185mm ARMATURE PLATE GUIDE PIN HOLE
[6mm(1/4") DIA, 12.5mm(1/2") DEEP]
STEP 1
STEP 4
FOLD TEMPLATE ALONG DOTTED LINE.
INSTALL MAGNET TO MOUNTING PLATE WITH
2 M6 SCREWS SUPPLIED.
PLACE TEMPLATE AGAINST DOOR AND HEAD FRAME.
DRILL HOLES AS INDICATED ON TEMPLATE.
STEP 5
INSTALL ELECTRICAL WIRING PER
STEP 2
INSTRUCTION SHEET.
MOUNT THE ARMATURE PLATE TO DOOR USING
STEP 6
1 RUBBER WASHER SANDWICHED BETWEEN 2 STEEL
WASHER (THE RUBBER WASHER AND 2 STEEL
TEST ALL FUNCTIONS OF THIS MODEL (SEE
WASHER ARE INSTALLED ON THE THROUGH SEXNUT
WIRING INSTRUCTION).
BETWEEN THE ARMATURE PLATE AND DOOR).
STEP 7
STEP 3
INSERT 2 LOCKING STOPPERS IN TWO END
DETACH MOUNTING PLATE FROM MAGNET BY REMOVING
PLATES,AND COVER WITH 4 mm SCREWS.
2 SOCKET CAP SCREWS. SCREWS COULD BE ACCESSED
THROUGH BOTTOM OF MAGNET.
STEP 8
INSTALL THE MOUNTING PLATE WITH 2 FLAT HEAD
INSERT 2 ALUMINUM CAPS TO COVER THE
SCREWS (THE 2 M5x15 FLAT HEAD SCREWS ARE
TWO M6 SCREW HOLES.
INSTALLED IN THE SLOTTED HOLES FOR ADJUSTMENT).
ADJUST MOUNTING PLATE SO THAT IT FORMS A RIGHT
ANGLE WITH THE ARMATURE PLATE.
USING THE MOUNTING PLATE AS A TEMPLATE,DRILL
NOTE: IF NEEDED, USE SMALL MAGNET TO
THE WIRE HOLE.
REMOVE LOCKING STOPPERS FROM HOLES.
DRILL AND INSTALL THE REMAINING MOUNTING SCREWS.
ARMATURE PLATE
See User's Guide 75.5643 for U-bracket
installation (to be used with glass doors).
L&Z BRACKET
75.5366.07 UL MAGLOCKS 20171130
75.5366.07 UL MAGLOCKS 20171130
75.5366.07 UL MAGLOCKS 20171130
(1/8")
DRILL 3.2mm HOLE
(2 PLACES)
PLACE AGAINST JAMB
OPPOSITE HINGES FOR
R.H.R. DOOR INSTALLATION
185mm ARMATURE PLATE
[6mm(1/4") DIA, 12.5mm(1/2") DEEP]
DWG. NO. 820001