Product:
Type:
Read the operating manual carefully before starting to use the vacuum
cleaner. It provides important instructions for the operation, safety, care and
maintenance. Keep the operating manual in a safe place and, in case you
sell the unit, hand it on to the next owner.
The manufacturer reserves the right to carry out modifications to the design
and equipment.
Any other work not covered by this operating manual must not be carried out.
Electro-technical tests must be carried out in accordance with the
accident prevention regulations (BGV A3) and in accordance with
DIN VDE 0701 Part 1 and Part 3. These tests are required in accordance with
DIN VDE 0702 at regular intervals and after repair or modification.
A dust-technical check must be carried out at least once a year by the
manufacturer or a trained person, e. g. for damage to the filter, dust-tightness
of the vacuum cleaner, function of the monitoring equipment.
The vacuum cleaners are successfully tested in accordance with IEC/
EN 60335–2–2.
1 Before use
▶ When unpacking, check that the delivery is complete and that
there is no transport damage.
▶ Before using, the operators should be provided with information,
instructions and training for the use of the vacuum cleaner
and the substances that it is to be used for, including the safe
procedure for the removal of the gathered material.
2 Only use original accessories
See enclosed sheet.
Further accessories are given in the special acessories list or
upon request.
3 Fields of application
For wet and dry suction cleaning. Not suitable for vacuuming
health hazardous dusts. The suction cleaner with socket and ON/
OFF automatic switching system is intended for the connection of
electric tools.
4 Assembly
When unpacking, check that the appliance is complete and that
there is no transport damage.
4.1 Container ⑫
Open the lock-in closures ⑭ of the 20-l and 32-l container, and
lift off the top section ①. Tip over the container and press in the
steering rollers with pivot ⑰ until they lock into place. Screw the
large wheels ⑮ onto the axles ⑯; see fig. A / O.
The supplied steel axle ⑯ for the 45-l container is pushed through
the guide on the container, after which the wheels ⑮ and steering
rollers ⑰ are mounted as indicated in fig. B.
The steering rollers ⑰ for appliances with 22-l, 35-l and 55-l
stainless steel containers with chassis crosshead are mounted as
indicated in fig. C.
Vacuum cleaner for wet
and dry applications
AS+
Original operatin instructions in German
Insert suction tube ⑲ (when contained in scope of supply) into the
container guide from above and push down until it engages.
4.2 Filters ⑧ - ⑪
Fitting the filters, depending upon the given model:
- Push the folded filter cartridge ⑩ in a straight manner over
the case ⑤, right up to the stop point, and lock the bayonet
mount ⑪; see fig. D. The folded filter is suitable for wet and dry
suction cleaning.
- Foam filter
To suction the water, first remove the folded filter; push the foam
filter ⑧ over the casing ⑤, see Fig. E
- Take hold of the paper filter bag ⑱ at the flang and push ver-
tically from above into the guide of the cyclone suction opening
⑬ until the stop point is reached. The bag must rest against the
container wall; see fig. F.
For stainless steel containers, push the flange onto the suction
opening at the bottom first and then at the top, then keep
pushing as far as it will go.
- The bag increases the dust retaining capacity and is
intended for hygienic disposal. Paper filter bags can only
be used for dry suction cleaning.
- Place the filter sack ⑨ in the container ⑫ respectively for
stainless steel containers slip over the edge of the container,
see fig. G.
Remove the filter for wet suction cleaning.
4.3 Top section ①
From time to time, or when the suction force decreases, take out
the motor protection filter ⑦ for cleaning; see fig. I. Place the top
section ① right-way-round on the container as indicated in fig. H.
Observe the anti-rotation protection. The paper filter bag ⑱ must
not be damaged, and the lock-in closure ⑭ must engage securely..
4.4 Socket with ON/OFF automatic switching system
For suction cleaners with socket and ON/OFF automatic switching
system.
The socket ②e is intended for the connection of electrical tools. In
the "0" switch setting, the socket can be used as an extension line
(e.g. for a light).
Connected load: Suction unit and appliance max. 16 A
WARNING! An electric tool must be switched off when it is connec-
ted. The socket is always live when the plug is inserted in a mains
socket, irrespective of the switch position
The suction openings of electric tools are not standard.
Consequently, an adapter (Rubber sleeve) 547275 is available that
can be shortened to fit the given electric tool.
For other suction connections contact your dealer or the manufac-
turer of the given electric tool.
GB - 19