PBI Dansensor CheckMate II Guide Utilisateur page 39

Table des Matières

Publicité

38
Guide utilisateur
Column Start pos.*
1
1
2
10
3
19
4
28
5
37
6
39
7
41
8
43
9
50
10
59
11
68
12
109
13
150
14
175
15
216
16
254
17
292
18
330
19
368
20
406
21
507
22
522
23
524
24
531
25
538
26
540
27
542
28
551
29
553
30
555
31
564
32
566
33
568
34
577
35
579
36
581
37
590
38
592
39
594
40
603
41
605
42
607
43
616
44
618
45
620
46
622
47
624
48
626
49
628
50
635
Total:
642
* Only when all elements are selected and format is ASCII.
** Length: Fixed length. When unicode length must be multiplied by 4.
Fixed decimal placement. Leading zero in numbers. Gas concentrations are always in % buth with ppm resolusion (regardless of accuracy) e.g. "020.9465"
Example:
000,8395;000,3200;098,8405;000,0000;0;0;0;000002;27/02/08;16:43:39;Product 2;
PBI-250831-H 12/2009
Serial data dump specification
Length **
Type
Description
8
Numeric
O2 [%]
8
Numeric
CO2 [%]
8
Numeric
Balance [%]
8
Numeric
CO [%]
1
Numeric
O2 alarm [0=No alarm 1=High Alarm 2=Low Alarm]
1
Numeric
CO2 alarm [0=No alarm 1=High Alarm 2=Low Alarm]
1
Numeric
CO alarm [0=No alarm 1=High Alarm 2=Low Alarm]
6
Numeric
Product number [Integer]
8
Text
Date [MM/DD/YY] / [DD/MM/YY]
8
Text
Time [HH:MM:SS]
40
Text
Product name [Text]
40
Text
Product barcode [Text]
24
Text
CheckMate II S/N [Text]
40
Text
User ID [Text]
37
Text
User field 1 [Text]
37
Text
User field 2 [Text]
37
Text
User field 3 [Text]
37
Text
User field 4 [Text]
37
Text
User field 5 [Text]
100
Text
Note [Text]
14
Text
SW version [Text]
1
Numeric
Measure mode
[0=Continuous, 1=manual spot, 2=auto spot 3=intermitted]
6
Numeric
Sample time [seconds]
6
Numeric
Measure delay at intermitted [minutes]
1
Numeric
Alarm 1 type [0=Off, 1=high, 2=Low]
1
Numeric
Alarm 1 gas [0=O2, 1=CO2, 2=CO]
8
Numeric
Alarm 1 concentration [%]
1
Numeric
Alarm 2 type[0=Off, 1=high, 2=Low]
1
Numeric
Alarm 2 gas [0=O2, 1=CO2, 2=CO]
8
Numeric
Alarm 2 concentration [%]
1
Numeric
Alarm 3 type[0=Off, 1=high, 2=Low]
1
Numeric
Alarm 3 gas [0=O2, 1=CO2, 2=CO]
8
Numeric
Alarm 3 concentration [%]
1
Numeric
Alarm 4 type[0=Off, 1=high, 2=Low]
1
Numeric
Alarm 4 gas [0=O2, 1=CO2, 2=CO]
8
Numeric
Alarm 4 concentration [%]
1
Numeric
Alarm 5 type [0=Off, 1=high, 2=Low]
1
Numeric
Alarm 5 gas [0=O2, 1=CO2, 2=CO]
8
Numeric
Alarm 5 concentration [%]
1
Numeric
Alarm 6 type[0=Off, 1=high, 2=Low]
1
Numeric
Alarm 6 gas [0=O2, 1=CO2, 2=CO]
8
Numeric
Alarm 6 concentration [%]
1
Numeric
Note [0=Off, 1=At alarm, 2=At no alarm, 3= Always, 4=Always]
1
Numeric
User field 1 required [0=no, 1=Always, 2=Once]
1
Numeric
User field 2 required [0=no, 1=Always, 2=Once]
1
Numeric
User field 3 required [0=no, 1=Always, 2=Once]
1
Numeric
User field 4 required [0=no, 1=Always, 2=Once]
1
Numeric
User field 5 required [0=no, 1=Always, 2=Once]
6
Numeric
Device temperature [°C]
6
Numeric
Atmospheric pressure [mbar]
Chars in ASCII (x4 in UNICODE) +CRLF
FR
COPYRIGHT ©
CheckMate II
Note
Fixed decimal point, eg. "020.9465"
Fixed decimal point, eg. "020.9465"
Fixed decimal point, eg. "020.9465"
Fixed decimal point, eg. "020.9465"
No decimal point (e.g. "000032")
Variable according to set-up
Left alligned
Fixed decimal point plus sign, eg. "+005.0"
No decimal point
Fixed decimal point, eg. "020.9465"
Fixed decimal point, eg. "020.9465"
Fixed decimal point, eg. "020.9465"
Fixed decimal point, eg. "020.9465"
Fixed decimal point, eg. "020.9465"
Fixed decimal point, eg. "020.9465"
Signed value and fixed point
(eg. "+023.0" or "-003.2")
No decimal point