Inductive signal transmission system

11. Taking out of service and disposal

The products manufactured by ASO are intended solely for commercial use (B2B). At the end of use, the
products are to be disposed of according to all local, regional and national regulations. Products can also be
returned to ASO, which will then dispose of them properly.

12. Technical specifications

Supply voltage
Terminal resistance of the safety contact edges
nominal value
upper switching point
lower switching point
Relay stages
Nominal current DC
Nominal current AC
Mech. life-time
Safety relay switching times
Switching off delay (response time)
Switching on delay
Assembly
Plug in card for vertically plugging into a controller with Phoenix
connector MSTBVA 2,5/11-G-5,08
Dimensions: (HxWxD)
Protection class
Weight
Temperature range
Connection cable cross-section
single- or fine-stranded cable 0,75-1,5 mm
Certifications (In accordance with INDUS rail 71-242)
DIN EN ISO 13849-1:2008 Category 3 PL e
MTTFd 170 years, DC 91%
Elektronik
MTTFd 1616 years, DC 99 %
Elektromechanik
B10d 1000000
MTTFd 190 years (Nop 52560)
Safety device acc. to DIN EN 12978
All voltages connected to the switching unit must
be safely isolated!
20
U
24 V DC ±10%
E
I
= 85 mA; I
= 180mA (100ms)
E
max
Stationary
contact edge
contact edge
R
= 8,2 kΩ
nom
R
> 12 kΩ
AO
R
< 5 kΩ
AU
3 A
30 V DC
3 A
30 V AC
>10
actuations
6
Stationary
contact edge
< 10 ms
500 ms (Power on 700 ms)
82 x 78 x 27 mm
IP00
115 g
-25°C to +55°C
2
Travelling
= 8,2 kΩ
> 20 kΩ
< 2,5 kΩ
Travelling
contact edge
< 30 ms
EC type-examination no.:
44 205 12 399386
Certificate no.:
44 780 12 399386
Test report no.:
12 205 399386-000

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

71-752

Table des Matières