Electrical Connection - GE AZ90E09 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions
1. REMOVE CONTROL BOX
PANEL
WARNING
disconnect on front of the chassis.
Failure to do so can result in personal injury and/or
death.
3. MAKE WIRE LEAD CONNECTIONS INSIDE THE CONTROL BOX
WARNING
RISK OF ELECTRIC SHOCK
Can cause injury or death. This appliance must
be properly grounded.
Turn OFF electrical power before service or
installation.
Pull the power disconnect located in the front of the
from the main breaker panel or the closet mounted
disconnect.
NOTE:
• All electrical connections and wiring must be installed
by a qualified electrician and conform to the National
Electric Code (NEC) and all local codes which have
jurisdiction.
• All chassis must be hard wired with properly sized
breakers. Use HACR type breakers to avoid nuisance
trips.
• Unit must be properly grounded.
49-7769
ELECTRICAL CONNECTIONS
Electric Shock Hazard
2. ATTACH CONDUIT
and clamp the conduit through the conduit clamp and
free from the end of the conduit.
Ground
Wire
UL-listed electrical connectors and techniques.
BE connected to the branch circuit ground wire.
by replacing the 7 screws removed earlier.
Ground
Wire
Conduit
clamp
Conduit
Conduit
L2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Az91h09Az90e12Az91h12Az90e18d c

Table des Matières