9
Cutting method
• Straight cuts (SEE FIG 14)
≤ 570 mm : the stop (C) prevents fingers
being trapped between the table and the
frame (SEE FIG 15).
> 570 et ≤ 650 mm : retract the stop (C)
under the table to increase the stroke.
A reversible and removable cutting guide enables
45° to 90° cuts to be made.
This cutting guide is machined in such a way that
it can be fitted in several positions in addition to its
right angle position from 0° to 45° to the left or to
the right.
10
Depth of cut adjustment
(SEE FIG. 16).
• Slacken off handle (6).
• Use lever (5) to adjust the cutting height.
• Tighten handle (6).
11
Maintenance (the motor must be stopped)
• Clean the machine regularly.
• Drain the tank (22) frequently to remove cutting
residue, which otherwise could block the pump
and cause it to wear out prematurely. (SEE FIG
17).
• Swill out the tanks (1) and (22) with water.
• Carefully clean the contact faces for the table
rollers.
Store in a dry place, not accessible to
children.
!
Maintain the tools carefully.
FAULT FINDING
In the event of faulty operation refer to the tables
below to find a solution.
• The machine does not work
CAUSES
Not plugged in proper-
ly or cable damaged
No mains voltage
Switch
defective,
motor cable damaged
Motor
faulty
(no
power,
unpleasant
smell)
• Difficult starting
CAUSES
Single phase motor
starting condenser
Three-phase
supply
not
correct
(on
2
phases, motor cable
faulty)
• The pump does not start
CAUSES
The mains lead is not
correctly connected or
is damaged
No voltage in pump
circuit or mains supply
circuit
• The pump does not pump water
CAUSES
An air bubble may
have formed inside the
pump body
The turbine is jammed
REMEDIES
- Make sure that the
supply is correctly
plugged
in
(plug,
extension lead, etc)
- Check the supply
cable
- Test or have tested
by an electrician (cir-
cuit breaker, plug,
etc)
- Have tested by an
electrician or contact
the service depart-
ment
- Contact the service
department to have
the motor replaced
REMEDIES
- Replace the
condenser
- Have it checked by
an
electrician
or
contact the service
department
REMEDIES
- Check
the
mains
lead
- Check the pump cir-
cuit and mains sup-
ply circuit
REMEDIES
- Holding the pump of
the outlet pipe remove
it from the water and
reimmerse it
- Unscrew the filter
and, using a small
screwdriver, remove
all dirt from the ope-
rating area of the tur-
bine.
23