This System has been tested according to ANSI/NSF 42 and 53 for
the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42 and 53.
Actual performance may vary with local water conditions.
To reduce risk of ingestion of contaminants, do not use with water
that is microbiologically unsafe or with water of unknown quality
without adequate disinfection before or after the system. Systems
certified for cyst reduction may be used on disinfected waters that
may contain filterable cysts.
Contaminant Reduction
Average Influent
Réduction de Contaminant
Affluent moyen
Reducción del
Promedio de Agua
Contaminante
Prefiltrada
Chlorine Taste and Odor/
2.0 mg/L
Goût et Odeur de Chlore/
Gusto y Olor del Cloro
Particulate**/ Particules/
5,633,333 pts/mL
Partículas
Asbestos/Asbeste/ Amianto
251 MFL
Atrazine/Atrazine/Atrazina
0.008 mg/L
Benzene/ Benzène Benceno
0.014 mg/L
Cyst/Spores/Quistes*
84,250 cysts/L
Lead/Plomb/Plomo
0.148 mg/L
pH @6.5
Lead/Plomb/Plomo
0.143mg/L
pH @8.5
Lindane/ Lindane/Lindano
0.002 mg/L
Mercury/Mercure/
0.006 mg/L
Mercurio @ pH 6.5
Mercury/Mercure/
0.006 mg/L
Mercurio @ pH 8.5
Turbidity/ Turbidité/
11 NTU***
Turbidez
VOCs/COV/COV
0.324 mg/L
Tested using a flow rate of 0.78 gpm; pressure of 60 psig; pH of 7.5 ± 0.5;
temp. of 68° ± 5°F (20° ± 3°C)
*Based on the use of Cryptosporidium parvum oocysts.
Operating Specifications
Capacity: certified for up to 160 gallons (605 l)
Flow rate: 0.6 gpm (2.3 lpm)
GE SmartWater
Specifications / Spécifications / Especificaciones
Ce système a été testé conformément aux normes ANSI/NSF 42
et 53 pour assurer la réduction des substances listées ci-dessous.
La concentration des substances spécifiées dans l'eau arrivant au
système a été réduite à une valeur inférieure ou égale à la limite
admise pour l'eau sortant du système tel que défini dans les normes
ANSI/NSF 42 et 53.
Les performances réelles peuvent varier selon les conditions de
l'eau fournie localement.
Pour réduire le risque d'ingestion de contaminants,
produit sans une désinfection adéquate avant ou après le système,
avec d'eau de qualité inconnue ou microbiologiquement polluée. Les
systèmes homologués pour la retenue des spores peuvent être
utilisés pour la filtration d'une eau désinfectée qui peut contenir des
spores filtrables.
NSF specified Challenge Concentra-
tion
% moyen de réduction
Concentration infiltrante spécifiée
par NSF
Desafío de la Concentración Especi-
2.0 mg/L ± 10%
At least 10,000 particles/mL
10
to 10
fibers/L; fibers greater
7
8
than 10μm in length
0.009 mg/L ± 10%
0.015 mg/L ± 10%
Minimum 50,000 cysts/L
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.002 mg/L ± 10%
0.006 mg/L ± 10%
0.006 mg/L ± 10%
11 +1 NTU***
0.300 mg/L ± 10%
Essayé en utilisant un taux de circulation de 0,78 gpm; pression de 60 psig; pH
de 7.5 ± 0.5; temp. de 20° ± 3°C (68°F ± 5°F)
*Basé sur l'utilisation d'oocystes de Cryptosporidium parvum.
**Mesure en particules/ml. Particules utilisés de 0.5-1 micron
Caractéristiques techniques de fonctionnement
Capacité certifiée pour jusqu'à 605 l (160 gallons); jusqu'à six mois
Exigences de pression : 35-120 psi (2,8-8,2 bar)
Température : 0,6-38°C (33-100°F)
Taux de circulation : 0,6 gpm (2,3 lpm)
ne pas utiliser ce
Avg % Reduction
Average Product Water Concentra-
tion
Concentration moyenne de produit
Reducción del %
dans l'eau
Promedio
Concentración de Agua sobre el
Producto Tipo
97.5%
0.05 mg/L
96.9%
174,500 pts/ml
99.99%
<1 MFL
94%
0.0005 mg/L
96.3%
0.005 mg/L
99.99%
5 cyst/L
99.3%
0.001 mg/L
99.3%
0.001 mg/L
98.8%
0.00002 mg/L
96.6%
0.0002 mg/L
96.6%
0.0002 mg/L
99.9%
<1 NTU
97.9%
.0007 mg/L
2
Este sistema ha sido probado de acuerdo con ANSI/NSF 42 y 53
para la reducción de las sustancias mencionadas más adelante. La
concentración de las sustancias indicadas contenidas en el agua
que entra al sistema fue reducida a una concentración menor o
igual al límite permitido para el agua que sale del sistema, según las
normas establecidas por ANSI/NSF 42 y 53.
El desarrollo real podría variar de acuerdo con las condiciones
locales del agua.
A fin de reducir el riesgo asociado con la ingestión de
contaminantes,
no debe usarse en aquellos lugares en los que
el agua no es microbiológicamente segura, o si se desconoce
la calidad del agua. Cerciórese de que el agua se desinfecta
adecuadamente, ya sea a la entrada o a la salida del sistema.
Sistemas certificados para reducción de quistes pueden ser usados
en agua desinfectada que podrían contener quistes filtrables.
Max Permissible Product Water
Concentration
Concentration maximale per-
missible du produit dans l'eau
Máxima Concentración de Agua
Tolerable sobre el Producto
N/A
N/A
N/A
0.003 mg/L
0.005 mg/L
N/A
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.002 mg/L
0.002 mg/L
0.5 NTU
N/A
Probado usando un ritmo de flujo de 0.78 gpm; presión de 60 psig; pH de 7.5 ± 0.5;
temperatura de 20º ± 3º C (68º ± 5º F)
*Basado en el uso de Cryptosporidium parvum oocysts
**Medidas en partículas/mL. Partículas usadas eran de 0.5-1 micrones
Especificaciones operativas
Capacidad: Certificado para un máximo de 605 litros (160 galones); hasta seis meses.
Temperatura: 0.6º - 38º C (33º - 100º F)
Ritmo de flujo: 2.3 lpm (0.6 gpm)
NSF Reduction
Requirements
Spécifications NSF de
réduction
Requisitos de Reducción
de NSF
N/A
N/A
N/A
N/A
N/A
N/A
N/A
95.5%

Publicité