eNet
Tecla sensora con receptor vía radio
Manual switchoff of the run
on time
Switchon brightness
Switchon delay
Switchoff delay
Dim up ramp
Dim down ramp
Dimming adjustment time
32582703
J:0082582703
On, Off
Basic setting: Off
1...100 %
Basic setting: 100 %
0 s ... 24 h
Basic setting: 0 s
0 s ... 24 h
Basic setting: 0 s
0 s ... 24 h
Basic setting: 0 s
0 s ... 24 h
Basic setting: 0 s
1...60 s
Basic setting: 4 s
6/10
Allows manual switchoff of a
running runon time. If the pa
rameter is switched off, then a
switchoff command will also
switch the actuator on. This
parameter is directly connec
ted to the "Runon time" para
meter.
During brief operation, the out
put switches on at the set
switchon brightness.
Note: If the value is above the
set maximum brightness or
below the minimum bright
ness, then the system will
switch to the appropriate limit
value.
The load switches on after a
delay. Repeated switchon
commands restart the delay
time. If the load has not yet
been switched on due to the
delay when a switchoff com
mand comes, then the load
will remain off.
The load switches off after a
delay. Repeated switchoff
commands restart the delay
time. If the load has not yet
been switched off due to the
delay when a switchon com
mand comes, then the load
will remain on.
Time between switchon and
reaching switchon brightness.
The light is switched on at mi
nimum brightness and then
dimmed to the switchon
brightness.
Note: If scenes are recalled or
switching uses logic modules,
the switchon brightness is ap
proached using socalled soft
dimming (not configurable).
Time until reaching minimum
brightness in case of switching
off (short operation). The light
is dimmed to minimum bright
ness and then switched off.
Note: If scenes are recalled or
switching uses logic modules,
the system switches off direct
ly.
Time from minimum bright
ness until reaching maximum
brightness (dimming speed).