strips along the edges of the opening in the bench top and carefully overlap the strip end. (See Fig. 3). insert
the hotplate into the bench top opening. With a screwdriver assemble the brackets to the hotplate bottom by
means of the screws . (See Fig. 3A-3B). Slide the hooks into position and secure them with the screws.
Trim the part of the sealing strips which extend beyond the hotplate base
IMPORTANT INFORMATION CONCERNING THE INSTALLATION OF THE APPLIANCE
The hob can be installed by itself, in an isolated position or inserted between two kitchen units or
between one kitchen unit and a wall. Furthermore the back wall and surrounding surfaces must
resist a temperature of 65 K.
To prevent the plastic layer which covers the kitchen unit from ungluing, the glue used to join the
two surfaces together must resist temperatures of up to 150 °C
The installation of the appliance must be carried out according to the norms in force of the country
concerned and the appliance must be installed in a well ventilated place.
This appliance is not equipped with devices to remove the products of combustion. The appliance
must therefore be connected following the norms for installation mentioned above. Special attention
must be paid to the information below regarding aeration and ventilation of the premises.
To guarantee that the appliance works correctly it is necessary that the place where the appliance is installed
is continuously ventilated. The volume of the premises must not be less than 25 m³ and the quantity of air
needed must be based on the regular combustion of gas and on the ventilation of the premises. The natural
flow of air will take place through permanent openings made in the wall of the premises to be ventilated:
these openings will be connected to the outside and must have a minimum section of 100 cm² ( see Fig. 4 ).
These openings must be made in such a way that they cannot be obstructed.
The cooking appliances that use gas must always remove the products of combustion via a hood linked to
chimneys, chimney flues or via a direct connection to the outside ( see Fig. 5A ). If it is not possible to fit a
hood it is possible to use a fan, fitted on the window or facing directly outside, which operates when the
appliance is in use. ( see Fig. 5B ). In this way the norms in force of the country concerned regarding the
ventilation of premises are strictly followed.
Before connecting the appliance to the gas supply you first need to remove the plastic protective
plug for the gas supply which is inserted under pressure in the gas inlet connection. To remove the
plug simply unscrew it.
Then make sure that the details shown on the label on the lower part of the case are compatible with
those of the gas supply.
A label on the last page of this manual and on the lower part of the case indicates the conditions for
regulating the appliance: type of gas and pressure used.
IMPORTANT: This appliance must be installed in accordance with the norms in force of the country
concerned and it must only be used in a well-ventilated place.
ATTENTION: Remember that the gas inlet connection for the appliance is threaded 1/2 gas
cylindrical male in accordance with the norms UNI-ISO 228-1. (Fig. 6-7)
CONNECTION OF THE APPLIANCE TO THE ELECTRICITY SUPPLY:
Connection to the electricity supply must be carried out according to the norms and indications of
the law in force.
Before carrying out the connection check that:
- The electric charge of the system and the sockets are suitable for the maximum power of the appliance (
see label on the lower part of the case ).
- The socket or system is equipped with an efficient earth connection according to the norms and indications
of the law currently in force. No responsibility can be held if these indications are not respected.
When the connection to the electricity supply is made with a socket.
Fit onto the electric cable a standard plug ( if it is not provided ) which is appropriate for the charge indicated
on the label. Connect up the wires according to the diagram in Fig. 8 taking care to respect the
corresponding pairs listed below:
letter L (phase) = brown coloured wire;
VENTILATION OF THE PREMISES
POSITION AND VENTILATION
CONNECTING THE APPLIANCE TO THE GAS SUPPLY