Télécharger Imprimer la page

Güde GLS 3000 VARIO Traduction Du Mode D'emploi D'origine page 12

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Service
Any technical questions? Complaint? Do you need
spare parts or operation manual?
Go to our website www.guede.com and the section
Service will help you quickly and without bureaucracy.
Please, help us to help you. In order to identify your device
in case of complaint, please indicate serial number, order
number and year of manufacture. All information is
available on the product label. To have all information
always at hand, put them down.
Serial number:
Order number:
Year of manufacture:
Phone:
+49 (0) 79 04 / 700-360
Fax:
+49 (0) 79 04 / 700-51999
E-Mail:
support@ts.guede.com
Important information for the customer
Please be sure to know that returning the product in or
after the warranty period must be made in the original
packaging.
Servicing
Switch the appliance off before any servicing
and cleaning and wait until it fully stops.
Unplug the appliance.
Servicing works not explicitly specified in this manual must
be performed by specialised staff as there might be
dangerous situations the operator is unable to handle.
Spare parts may only be replaced by specialised staff.
Proceed as follows when the appliance is
blocked:
The suction/blowing tube may only be disassembled for
cleaning purposes. It must be properly refitted after
finishing the cleaning!
Cleaning
The appliance must not be cleaned by high-pressure
cleaners or under running water.
Do not use any aggressive, caustic cleaning agents.
After finishing your work, remove the collection bag
and turn it inside out. Clean the bag properly;
otherwise, mould and unpleasant smell could be
produced.
A severely dirty collection bag can be cleaned by
water and soap.
Keep the appliance and ventilation slots clean and
free at all times.
Any dirt on the appliance can be removed by a wet
cloth. Clean the suction tube with a wet cloth or
brush.
Troubleshooting
The table shows potential failures, their possible cause
and removal options. However, if you are unable to
remove the problem, contact a professional to assist you.
Switch off and unplug the appliance before any
servicing and cleaning.
Symptoms
Possible cause
No system voltage
Cable is defective
Appliance not
starting
Collection bag is
not mounted
Couplings on the
engine are not
tightened properly
Collection bag is
full
Appliance not
Suction tube is
sucking
blocked
Switch to "Blowing"
Appliance not
Switch to "Suction"
blowing
12
Remedy
Check the plugging
and protection
To be checked or
replaced in the
customer service
centre.
Collection bag mount
so that the limit switch
is actuated.
To be checked or
replaced in the
customer service
centre.
Empty the collection
bag
Clean the suction tube
Switch to "Suction""
Switch to "Blowing"