6. Starting aid function
6 - 24V 80A arithm. / 100 A eff.
1. Set the battery voltage (6V / 12V or 24V).
2. Set the current level switch to level 6 (Figure 1).
1
1
6
5
4
3. Pre-charge the battery for 5 - 10 minutes as described in section 3 „Charging the battery".
4. Press the pushbutton of the remote starting unit and simultaneously start the vehicle
(Fig. 2).
2
The overload switches will switch off the charger after a short time. If you fail to start the
vehicle, you can reset the head of the overload switch after approx. 3 minutes and repeat the
starting operation. Starting is easier if you charge the battery for approx. 5 minutes at
maximum charging level prior to starting.
12