Ndustrio 090VTR Manuel D'utilisation Et D'installation page 36

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

CONVERSION OF ELECTRICITY SUPPLY
Important
The appliance is supplied at an operating
voltage 400V/3N (indicated on the sticker
applied to the dataplate); conversion to
230V/3 - 230V/1N (only for 090VTR) can be
carried out as described below.
Caution - warning
Before doing any work, cut off the mains
electricity supply.
1 - Undo the screws (A) and remove the control
panel (B).
2 - Modify the connections of the terminal board
as shown in the diagram and in the electrical
system diagram at the back of the manual.
3 - Replace the control panel (B) on comple-
tion of the operation.
4 - Remove the test voltage indicator sticker from
the dataplate and apply the new one to identify
IT
the voltage being used
GB
Important
On completion of the operation make sure
DE
that there are no malfunctions.
FR
ES
English
- 16 -
B
A
IDM-39603620000.tif