Error Code

If the appliance malfunctions, a beep alarm will sound and the an error code will display on the wall controller. Write down the
error code, then try resolving by stopping and restarting the water flow, or resetting the appliance as follows:
● Switch the power switch (Fig. 18) in front of the water heater to the "OFF" position.
● Wait 5 seconds.
● Switch the appliance on again.
Continue to use the appliance normally. If error fault codes continue to display, review the following table for potential causes.
Error Code
E0: Water outlet
temperature
E1: Flame sense during
igntion
E2: Detected fake flame
signal
E3: Over temperature
mechanical sensor faulty
E4: Water inlet temperature
E5: Air pressure
E6: Temperature Surge
E7: Solenoid valve fault
15
Possible Cause
System Fault.
Insufficient Fuel Supply to start
operation.
Low gas inlet pressure.
System Fault.
System Fault.
System Fault.
System Fault.
Exhaust Blockage.
High winds blowing on exhaust.
System Fault.
Cold water surge in system.
Cold water mix ratio.
Insufficient water supply.
Insufficient Water flow.
System Fault.
System Fault.
Contact Furrion.
Confirm all gas valves are open,
Confirm adequate fuel in tanks.
Check regulator for operation, replace if needed.
Contact Furrion.
Contact Furrion.
When E3 error displays, let cold water flow 10~20S then restart the appliance.
If E3 still displays, contact Furrion.
Contact Furrion.
Remove obstruction, then restart the appliance.
Move or re-orient coach so exhaust is not facing high winds, then restart the appliance.
Contact Furrion.
Reduce toilet flushes and amount of cold water faucets opened during operation.
Reduce temperature setting to reduce cold water mix ratio.
Check for shower head and outdoor faucet valves leaking cold water to hot side.
Confirm water tank is full or city water valve fully open.
Air in water lines - continue to run all faucets, Hot and Cold, open until air purged.
Filter plugged - review "Cleaning and Maintenance" section of this manual.
Low flow faucets - check that the minium flow is .32gpm.
Contact Furrion.