5.MAINTENANCE AND CLEANING
Warning: Always switch off and unplug the appliance before cleaning it or changing the filter. To
unplug the unit, be sure to unplug the plug and not the cord. Do not use any tools other than those
recommended for the manufacturer.
1.Surface cleaning
Regularly clean the exterior of your air purifier, to prevent dust from accumulating, with a soft or slightly damp
cloth. Never use chemical or flammable reagents, such as benzene, alcohol and gasoline. Otherwise, you risk
damaging the surface of your device or even the entire operation of the device itself.
2.Cleaning the filters
If the filter is covered with dust, it may obstruct air circulation and thus reduce the efficiency of the product.
When the machine detects the filter is saturated after running for 2200 hours, the filter indicator light will keep
flashing in red. Long press the filter button for 7s to stop flashing light and to reset after installing a new filter
CAUTION: it is important to change your filter following the alert. When you turn off the filter change
alert, it automatically restarts whether you have changed your used filter or not, it is stopping the alert
that starts a new cycle of 2200 hours and not the filter change. After 2200 hours of use, the filter change
alert will sound again. To ensure proper use and efficiency of your product, it is essential to change the
device filter when the filter change alert indicates it. A used filter can affect the life of your device and
no longer purify the ambient air.
3.Remplacing the filter
27