1) GENERAL OUTLINE
BTBAT mod. buffer battery kit.
Allows the automation system to operate even when
the mains power supply is disconnected for a short
time.
The pack is made up of:
2 battery back up units (ref. B).
1 battery charger board (ref. SBS).
1 battery fixing bracket
Connection cables, spacers, screws.
Fitting instruction manual.
Note: The BT BAT kit is also available already
assembled and prewired on a SD box, to be used for
all the LIBRA boards and the HYDRA boards fitted
inside the operator (Fig. 3).
2) SBS BOARD AND BATTERY SPECIFICATIONS
Charge voltage: .......................................... 27.2Vdc
Charge current: ............................................. 130mA
Data detected with external temperature of: ... 25°C
Battery capacity: .............................. 2x (12V 1.2Ah)
Exhausted battery protection threshold: .... 20.4Vdc
Battery recharging time: .............................. 12/14 h
3) FITTING
All the fitting and connection operations must be
carried out by qualified personnel.
To fit this accessory, proceed as specified below.
BT BAT to be fitted to a Hydra QSG control panel
-
Disconnect the power supply.
-
Fix the board in the position shown in Fig. 4, using
appropriate spacers "D" supplied as standard.
-
Then fix the batteries, using the appropriate bracket
as shown in Fig. 4.
-
Carry out connections as shown in the diagram in
Fig, 1 for the LIBRA control panel and diagram in
Fig. 2 for HYDRA panel.
BT BAT preinstalled on SD box
-
Disconnect the power supply.
-
Carry out connections as shown in the diagram in
Fig, 1 for the LIBRA control panel and diagram in
Fig. 2 for HYDRA panel
IMPORTANT NOTE: In the panels supplied by battery
back up power, the "24Va.c." and "Vsafe 24Va.c."
outputs have a 24Vd.c. voltage, polarised as shown
in Fig. 1 for the LIBRA board and in Fig. 2 for the
HYDRA board.
At the time of installing the BT-BAT kit, check that the
devices supplied by these outputs are correctly
connected.
4 - BT BAT - Ver. 02
INSTALLATION MANUAL
4) BATTERY REMOVAL
1) Remove the batteries before dismantling the
2) The batteries must be discarded safely.
3) The appliance must be disconnected from the
Having disconnected the power supply. remove the
wiring existing between the batteries and the SBS
board.
Then, remove the fixing bracket S and dispose of the
batteries according to whatever prescribed by the
current regulations.
The descriptions and illustrations contained in
the present manual are not binding.
The Company reserves the right to make any
alterations deemed appropriate for the technical,
manufacturing and commercial improvement of
the product, whileleaving the essential product
features unchanged, at any time and without
undertaking to update the present publication.
When removing the batteries, observe the
current regulations and in particular:
operator.
power supply during battery removal.