Operation - Pattfield Ergo Tools PE-HWA 650 Traduction De La Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
5.4 Electrical connections
Connect the appliance to a 230 V ~ 50 Hz socket-outlet with
earthing contact. Minimum fuse 10 ampere.
A built-in thermostat protects the motor from overloading and blo-
cking. The pump is switched off automatically by the thermostat if
overheating occurs and is switched on again automatically after
cooling.

6. Operation

Install the equipment on a solid and level surface.
Fill the pump housing with water via the water filler screw (7). Fil-
ling the intake line will accelerate the priming process.
All the shut-off devices in the discharge line (spray nozzle, valves
etc.) must be fully opened during intake in order to permit all air to
escape from the intake line.
Connect the mains cable.
Switch on the equipment with the power switch (4) - water can be
suctioned in for up to 5 minutes (maximum suction height).
After finishing the work, switch off the equipment with the power
switch (4).
The fl ow switch cannot be adjusted or switched, it is fully automatic.
There are only 3 LEDs (Fig. 3 / Item 8) to indicate its operating status.
Green LED:
The fl ow switch is connected to the power supply
Yellow LED:
The fl ow switch has tripped, the socket (Fig. 2 / Item 2) is live.
Red LED:
The fl ow switch has detected a fault