Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
ATTENTION!
Always wear a respirator and gloves during exchange/
cleaning of spark arresters and emptying dust
collection tray/dust container(s).
ATTENTION!
Industrial vacuum cleaner used during service and
maintenance should meet dust class H according to
EN 60335-2-69.
4

INSTALLATION

4.1
Unpacking
Check that the product is complete. The package should
contain:
- dust collection tray
- 2 cover plates
- work grid (two-piece)
- backdraft panel
- frame with vertical lamellas (2)
- 2 side panels
- 4 legs
- 4 adjusting feet
- 2 leg covers
- fixing material
If parts are missing or damaged, contact your supplier.
4.2
Installation
To mount the DraftMax Eco, proceed as follows.
Refer to Fig. I to Fig. VIII on page 26.
Fig. I
Assemble the 2 legs; adjust them at the desired
height.
Fig. II
Mount the dust collection tray on the legs.
Fig. III •
Mount the cover plates (A) or insert one or two
optional dust containers (B).
Fig. IV
Mount the backdraft panel.
Fig. V
Mount the side panels.
Fig. VI
Mount the connection piece (option).
Fig. VII A: No optional spark arresters:
Place the vertical lamellas and fasten them.
B: Optional spark arresters:
Unscrew the vertical metal strip from the
backdraft panel.
Place the spark arresters.
Place the metal strip in between the two spark
arresters and fasten it.
Place the vertical lamellas and fasten them.
Fig. VIII •
Loosen the ground brackets.
Place the work grids (A).
Place the ground brackets (B) over both work
grids.
Tighten the ground brackets.
4.3
Installation remaining options
Refer to Fig. IX to Fig. XI on page 27
Fig. IX
Plasma cutting work grid:
Remove the ground bracket at the position of the
work grid. Keep the bolts.
Place the frames.
Fasten the frames using the 2 bolts (A).
Place the bars (B).
The supplied standard work grid, ground bracket and
the perforated steel spark arresters become
redundant.
0507061410 DraftMax Eco
Fig. X
Working light:
Mount the lighting fixture using the 6 bolts (A).
Lead the cable down the back side of the downdraft
table.
Attach the cable to the backdraft panel using the 3
tie-wraps (B).
Connect the cable to the power supply.
Fig. XI
Bench vice mounting bracket:
Position the mounting bracket on the grid.
Place the strips underneath the grid and fasten
them using the bolts, nuts and washers.
1. Power supply connection to be arranged by a certified engineer. If
necessary, cut/exchange the plug.
WARNING!
It is necessary to apply the bracket (in case of
standard work grid) or the bolts (in case of plasma
cutting work grid) to ground the work grids.
The downdraft table can be positioned using a fork-lift truck.
Position the downdraft table against the wall.
CAUTION!
Do not position the product where it is exposed to
vibrations or heat radiation from heat sources.
Observe the earlier described ambient conditions.
Fasten the downdraft table to the floor using key bolts.
Connect the air outlet (on top of backdraft panel) or the
optional connection piece to an external extraction/filtration
facility. For recommended extaction capacity and pressure
drop data refer to section 1.4.
5

USE

5.1
Downdraft table
To use the downdraft table, proceed as follows.
Switch on the connected extraction/filtration facility.
Start welding/grinding/cutting.
After finishing the job, switch off the connected extraction/
filtration facility.
5.2
Replacement of optional spark arrester
If the optional spark arresters are damaged or saturated, they
need to be replaced. To replace the spark arresters, proceed as
follows.
ATTENTION!
Always wear a respirator and gloves during
replacement of spark arresters.
Loosen the vertical lamellas.
Unscrew the metal strip in between the two spark arresters.
Unpack the replacement spark arresters and keep the plastic
bag.
Take out the used spark arresters and pack them in the
plastic bag in which the new ones are supplied.
Clean housing of backdraft panel, using an industrial vacuum
cleaner (HEPA where required) and wet wiping methods.
Place new spark arresters and mount the dismounted parts
in reverse order.
Dispose of the used spark arresters in accordance with
federal, state and/or local regulations.
1
EN - 4

Publicité

Table des Matières
loading

Table des Matières