6
MAINTENANCE
The product has been designed to function without problems for
extended periods with minimum maintenance. In order to
guarantee optimal performance level, regular maintenance and
cleaning activities are required which are described in this
chapter. If you observe the necessary caution and carry out the
maintenance at regular intervals, any problems occuring will be
detected and corrected before they lead to a total breakdown.
The indicated maintenance intervals can vary depending on the
specific working and ambient conditions. Therefore it is
recommended to thoroughly inspect the complete product once
every year in addition to the indicated periodic maintenance. For
this purpose contact your supplier.
WARNING
Overdue maintenance can cause fire.
6.1
Periodic maintenance
The maintenance activities in the table below are strictly
reserved for well trained and authorised service engineers.
Text printed in italics refers to options and accessories.
ATTENTION!
Always wear a respirator and gloves during
maintenance.
Clean spark arresters, dust collection tray and optional
dust container(s) preferably using an industrial
vacuum cleaner that meets dust class H according to
EN 60335-2-69.
Component
Action
Dust collection
Clean dust collection tray. Dust
tray
collection tray can be emptied:
- using an industrial vacuum cleaner
(preferred way)
- sweeping the dust into the optional
dust container(s)1
- using a dustpan and brush
Spark arresters
Clean spark arresters using an
industrial vacuum cleaner. Replace if
necessary (refer to section 5.2).
Dust
Empty the dust container(s).
container(s)
1)Connected extraction/filtration facility should be switched on during
cleaning.
7
TROUBLESHOOTING
If the downdraft table does not function (correctly), consult the
checklist below to see if you can remedy the error yourself.
Should this not be possible, contact your supplier.
Text printed in italics refers to options and accessories.
Symptom
Problem
Poor
Downdraft
extraction
table does not
capacity.
function
properly.
Working light
No light.
not working
0507061410 DraftMax Eco
Frequency
Every 2
weeks
X
1
X
X
Possible cause Solution
Spark arresters
Clean or replace
polluted.
spark arresters.
Cable is not
Connect cable.
connected.
Fluorescent light
Replace fluorescent
is defective.
light.
8
SPARE PARTS
Contact your supplier.
9
DISPOSAL
After life of the product, dispose it of in accordance with state or
local regulations.
CE DECLARATION
CE declaration not applicable.
EN - 5