Télécharger Imprimer la page

Elesa DD52R-E-RF Mode D'emploi page 26

Masquer les pouces Voir aussi pour DD52R-E-RF:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

DD52R-E-RF
The available parameters and their descriptions are listed in the following table.
Parameter
dir
OriGin
OFFSET
StEP
rES
diSPL
SPEEd
rAdio
P_toll
_ _ _ _ _ 0
EN
26
Description
Rotation
direction
Absolute
reference
value
Compensation
values
(Offset)
Reading
after one revolution
Resolution
Display orientation
Reading max speed
[rpm]
Parameters to be
networked to the
UC-RF control unit
via radio frequency.
Tolerance of target
position
Key function
Electronic position indicators
Data transmission via radio frequency
Available options
--o clockwise
o-- counterclockwise
-99999 ; 99999
The parameter value depends
on the unit of measure selected.
-99999 ; 99999
The system allows you
to store up to 10 compensation
values:
OFS 0 ... OFS 9
The parameter value depends
on the unit of measure selected.
0.01 ; 100.00
mm:
1 ; 0.1 ; 0.01
inches: 0.001 ; 0.01 ;
0.1 ; 1
degrees: 0.01 ;
0.1 ; 1
0° :
display right
180° : display reverse
300 ; 600 ; 1000
nEt id: id0...id9
nEt ch: ch01...ch36
0.01 ; 9.99
The parameter value depends
on the unit of measure selected.
ALL : selectable units of
measure: mm, inch, D
nodEG : selectable units of
measure: mm, inch
OFF : the key does not allow the
unit of measure conversion
Models all rights reserved in accordance with the law.
Always mention the source when reproducing our drawings.
Standard
value
--o
0
0
001.00
mm: 0.1
inches:
0.01
degrees: 1
600
id0
ch01
0.05
ALL

Publicité

loading

Produits Connexes pour Elesa DD52R-E-RF