Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6. Specifications

MODEL
CAPACITY*
INPUT
Low Line Transfer
Voltage
Low Line Comeback
Range
High Line Transfer
High Line Comeback
Frequency Range
Phase
Power Factor
OUTPUT
Output voltage
AC Voltage Regulation (Batt. Mode)
Frequency Range
Frequency Range (Batt. Mode)
Overload
Current Crest Ratio
Harmonic Distortion
AC Mode to Batt. Mode
Transfer
Time
Inverter to Bypass
Waveform (Batt. Mode)
EFFICIENCY
AC Mode
Battery Mode
DISPLAY AND SOUND ALARMS
Display
Sound alarms
BATTERY
Battery Type
Numbers
Standard
Recharge Time
Model
Charging Current
Charging Voltage
Battery Type & Numbers
Charging Current
Long-run
Model
Charging Voltage
PHYSICAL
Dimension, D X W X H
Standard
Model
Net Weight (kgs)
Dimension, D X W X H
Long-run
Model
Net Weight (kgs)
ENVIRONMENT
Operation Humidity
Noise Level
MANAGEMENT
Smart RS-232 or USB
Optional SNMP
NORMS
Standard
Electromagnetic compatibility
Low voltage safety
SALES INFORMATION
Warranty
EAN codes - standard version
EAN codes – extended backup time version (S)
* Reduce capacity to 60% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 208VAC. **Product
specifications are subject to change without further notice. Low voltage (110V) and High Voltage (220V) models are different products.
INFOSEC UPS SYSTEM – 15, Rue du Moulin – 44880 Sautron – France – www.infosec-ups.com
41
Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – hotline@infosec.fr – 03 17 AA 59 209 09
E4 LCD Pro 1000 (S) E4 LCD Pro 1500 (S) E4 LCD Pro 2000 (S) E4 LCD Pro 3000 (S)
1000 VA / 900 W
90VAC/80VAC/70VAC/60VAC±5% or 180VAC/160VAC/140VAC/120VAC±5%
(Ambient Temp.<35
(Ambient Temp.<35
(Synchronized Range)
105%~110%: UPS shuts down after 10 minutes at battery mode or transfer to bypass
110%~130%: UPS shuts down after 1minute at battery mode or transfer to bypass when
>130%:UPS shuts down after 3 seconds at battery mode or transfer to bypass when the
27.4 VDC ± 1%
2
27.4 VDC
± 1%
282 X 145 X 220 (mm)
282 x 145 x 220 (mm)
4.1
3700085 67230 3
3700085 67236 5
1500 VA / 1350 W
0
C)
(based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
100VAC/90VAC/80VAC/70VAC or195VAC/175VAC/155VAC/135VAC ± 5 %
0
C)
(based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
145 VAC ± 5 % or 300 VAC ± 5 %
140 VAC ± 5 % or 290 VAC ± 5 %
Single phase with ground
≧ 0.99 @ 220-230 VAC (input voltage)
110/115/120/127VAC or 208/220/230/240VAC
47 ~ 53 Hz or 57 ~ 63 Hz (Synchronized Range)
50 Hz ± 0.5% or 60Hz ± 0.5%
when the utility is normal
≦ 3 % THD (linear load); ≦ 6 % THD (non-linear load)
88%
83%
Battery mode, Low Battery, Overload, Default.
2
4 hours recover to 90% capacity (Typical)
3
4
41.0VDC ±
54.7 VDC
1%
±1%
397 X 145 X 220 (mm)
9.8
4.1
6.8
20-90 % RH @ 0- 40°C (non-condensing)
Less than 50dBA @ 1 Meter
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC
Power management from SNMP manager and web browser
EN 62040-2:2006+AC:2006; EN61000-3-2:2006+A1:2009+A2:2009
EN 62040-1:2008+A1:2013
3700085 67274 7
3700085 67275 4
2000 VA / 1800 W
40Hz ~ 70 Hz
±1% (Batt. Mode)
the utility is normal
utility is normal
3:1
Zero
4 ms (Typical)
Pure Sinewave
89%
87%
LCD Screen
12V / 9Ah
4
1A (max.)
54.7 VDC ±1%
6
8
1A/2A/4A/6A
109.4VDC
82.1VDC ±1%
±1%
17
397x 145 x 220(mm)
6.8
6.8
CE ROHS
2 years
3700085 67231 0
3700085 67237 2
3000 VA / 2700 W
90%
88%
6
82.1 VDC ±1%
6
8
82.1 VDC
109.4VDC
±1%
±1%
421 X 190 X 318 (mm)
27.6
7.4
7.4
3700085 67232 7
3700085 67238 9

Publicité

Table des Matières
loading

Table des Matières