4. Connect the low voltage wires to the wall bracket's connector in accordance with
the table below.
1
GND
2
AHU1
3
AHU2
4
SW2
5
SW1
6/7/8
N/A
For standard installation, only the low voltage wires
connections (#4 and #5) are used.
C.Axpir Initia must be wired to inlet valves.
C.Axpir Comfort works wireless and only needs a wired
connection in the case of a crumb plinth.
5. Connect the low voltage connector to the outer frame of the wall bracket.
6. Place the outer frame of the wall bracket vertically on top of the inner part of the
wall bracket.
7. Attach the outer frame of the wall bracket to the inner part with screws (5x20
mm TX20).
Use the mounting lugs on the outer frame of the wall bracket for additional
fastening, if necessary.
(If mounting on a partition wall stud, for example. Screws not included in
delivery.)
8. Connection to ducting
8A - Installation with Ø 51 mm ducting
1
Ø 51 mm 90° long F-F elbow - input side
Ground. Do not use.
AHU operation. Voltage free contact 24 VAC/
DC, 1 A. (C.Axpir Initia only)
AHU operation. Voltage free contact 24 VAC/
DC, 1 A. (C.Axpir Initia only)
Low voltage wires (wall inlet control)
Low voltage wires (wall inlet control)
Do not use
2
EN
Minimum 45 mm
length of Ø 51 mm
pipe - output side
13