Mobile Dust Extractor; Stationary Extraction System Turbo; Power Supply; Power - Festool EAA Notice D'utilisation D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
9.1

Mobile dust extractor

CT mobile dust extractors, series CT 22,
CT 33, CT 44, CT 55
X
Fit the assembly set (module EAA CT22/
33/44/55: 495756) for the control cable
to the CT mobile dust extractor (see as-
sembly instructions).
CT mobile dust extractor series CT 26,
CT 36
X
Fit the assembly set (module EAA CT26/
36: 494896) to the CT mobile dust extrac-
tor (already fitted on CTM 36 LE and CTL
36 LE models).
X
Plug the control cable into the socket on
the extractor.
SRM mobile extractor and other brands
of extractor
Connecting the control cable is no longer
possible. If the dust extractor has an appli-
ance socket with automatic switch-on unit,
the mains cable on the EAA must be plugged
into this appliance socket so that the auto-
matic switch-on unit on the dust extractor
functions. However, note the maximum ca-
pacity of the appliance socket. Not all EAA
functions can be used. We therefore recom-
mend using a Festool mobile dust extractor.
X
Plug the extractor hose into the extractor
opening on the dust extractor.
L We recommend using rotating adapter
D50 DAS-AS to connect the extractor
hose to the dust extractor.
L If the EAA is quite far away from the mo-
bile dust extractor, part of the extractor
hose should be replaced by a plastic pipe
or a steel pipe designed for extraction
systems (diameter 50 mm). This reduces
the air flow resistance in the extraction
line and improves the suction power at
the EAA.
9.2
Stationary extraction system
TURBO
X
Plug the control cableinto the socket on
the extraction system.
X
Plug the extractor hose into the extractor
opening on the extraction system (D75).
10

Power supply

Power and compressed air is supplied
through the energy box.
10.1

Power

All EAA versions have three sockets. Socket
[1-3]
is connected permanently to the power.
The two sockets AUTO 1
[1-5]
are live when the selector switch
is set to the "AUTO" position. If the switch is
set to "0" or "MAN", the sockets are discon-
nected from the power supply.
CAUTION
Risk of accident, electric shock
X
If tools are operated from all three sockets
simultaneously,
available at each socket is 1200W.
X
If the mains cable on the EAA is plugged
into the appliance socket on a dust extrac-
tor (see chapter 9.1), always observe the
maximum capacity of the appliance socket
on the dust extractor. The total power
supplied via the output cables on the three
EAA sockets must not exceed the maxi-
mum capacity of the appliance socket on
the dust extractor.
10.2

Compressed air

The EW versions have a non-adjustable
connection for unlubricated compressed air
[1-11].
CAUTION
Risk of accident, electric shock
X
The compressed air from this connection
cannot be adjusted, the pressure from the
in-house compressed-air system is sup-
plied to this connection. Festool com-
pressed
air
sanders
attached via this connection.
EW/DW versions have a maintenance unit
(see Fig.[2]), consisting of a pressure regu-
lator[2-1], manual condensate trap
and lubricator [2-6], two adjustable connec-
tions for lubricated compressed air
a non-adjustable connection for unlubricated
compressed air [2-7]. The flow pressure pre-
set at the pressure regulator is supplied to all
three connections. The two connections for
lubricated compressed air are for attaching
pneumatic tools.
The following is required for correct opera-
tion:
EAA
[1-9]
and AUTO 2
[1-4]
the
maximum
power
should
not
[2-8]
[1-6]
GB
be
and
23

Publicité

Table des Matières
loading

Table des Matières