ball-bearing jointed extraction arm
KUA-ATEX
A.
If the arm will not stay in the required position:
1.
Loosen the hose at A.
2.
Pull the extractor out to its full length and angle it horizontally.
Loosen the friction brake until the arm drops towards the floor.
Tighten until it no longer drops.
3.
If the arm is difficult to move sideways or moves on its own sideways,
then adjustments must be made to the friction collar. This is done by
either loosening or tightening the screw.Use an allen key.
B.
If the outer arm will not stay in the required position:
1.
Angle the outer arm horizontally. Loosen the friction brake until the arm
drops towards the floor. Tighten until it no longer drops.
C.
If the hood will not stay in the required position:
1.
Loosen the hose at C.
2.
Adjust the friction (see picture) until the hood will stay in the exact position.
D. Check
1. Check on a regular basis ground connection between hood and duct with
instrument or buzzer
2. When replacing hoses the ground connection must be
checked.
.
Declaration of conformity
We, PlymoVent AB, hereby declare under sole responsibility that the product KUA-
ATEX conforms to the following standards: EN 292-1, EN 292-2, EN 50014
and EN 13463-1 according to the directive, 98/37/EG and ATEX 94/9/EC.
The product is classified to category 2, group IIB and can be used in zone 1 (gas,
solvent) and 21 (dust).
This declaration will cease to be valid if any modifications are made to the product
without our express approval.
PlymoVent AB
Sågvägen 19
921 28 LYCKSELE
Lennart Wallberg
R&D Manager
0000101887/071013/A KUA/ATEX
mAInTEnAncE InSTrUc-
TIon
Date: 04-08-04
Product no:
KUA-2-ATEX
KUA-3-ATEX
KUA-4-ATEX
KUA/EN/5/8
EN - 15