Télécharger Imprimer la page

Abicor Binzel ABIPLAS CUT HF Mode D'emploi page 53

Publicité

Les langues disponibles

Les langues disponibles

®
ABIPLAS
CUT HF
7.2 Connecting the plasma cutting torch
Requirements for connecting the torch
1 Only use compressed air which is free from dirt, oil and water.
2 Ensure that the connections are properly assigned and tightened.
3 Ensure that the correct air pressure (flow pressure) and correct air volume are set. Insufficient
air volumes can lead to the torch overheating.
NOTICE
• The lower the pilot current, the longer the service life of the electrode and the
cutting nozzle.
• Make sure that the connections are properly assigned and tightened.
• Since the plasma nozzle cannot be protected against direct contact for technical reasons,
the plasma cutting power source must fulfil the requirements of EN 60974-7, point 7.4.2.
• When used with the plasma power source, the plasma cutting torch must conform to
EN 60974-10.
• The plasma power source must also conform to EN 60974-1.
• The plasma power source and cutting torch must have the same type of ignition (contact
or HF) and the same output power (rated current and corresponding duty cycle).
 Tab. 2 General torch data (EN 60974-7) on page EN-6
7.2.1 Compressed air as plasma and cooling gas
NOTICE
• Precisely setting the compressed air pressure and volume is important for the pilot arc
ignition, cut quality and service life of the torch and wear parts.
• An inlet pressure (p) smaller than specified results in thermal overload. The correct torch
pressure must be ensured by properly setting the pressure monitor on the power source.
 Tab. 3 Product-specific torch data (EN 60974-7) on page EN-6
BAL.0716.0 • 2022-01-11
7 Operation
EN - 23

Publicité

loading