Télécharger Imprimer la page

Estia HWS-1501CSHM3-E Manuel D'installation page 3

Masquer les pouces Voir aussi pour HWS-1501CSHM3-E:

Publicité

Les langues disponibles

Les langues disponibles

AIR TO WATER HEAT PUMP SYSTEM
1.0
2.0
EN
4
IMPORTANT INSTALLATION POINTS
1.1
The unit, for use with the ESTIA air to water heat pump system, is a purpose
designed unvented water cylinder.
1.2
The water cylinder MUST be fitted with a Pressure Relief Valve that complies
with your local Plumbing and Building Regulations. FAILURE TO PROVIDE
ADEQUATE PRESSURE RELIEF WILL INVALIDATE ANY GUARANTEE
AND LEAD TO A DANGEROUS INSTALLATION.
1.3
Where the inlet pressure exceeds 0.6 MPa (6 bar) a Pressure Reducing Valve
(set at max. 0.5 MPa (5 bar)) should be fitted to the inlet supply to the water
cylinder.
This MUST NOT be fitted between the Pressure Relief Valve and the water
cylinder.
1.4
A Check (non-return) Valve should be fitted to the inlet supply to the water cylinder.
This MUST NOT be fitted between the Pressure Relief Valve and the water cylinder.
1.5
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience or
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
INSTALLATION – GENERAL REQUIREMENTS
2.1
National Wiring Regulations may contain restrictions concerning the installation
of these units in certain areas, eg. Bathrooms.
2.2
The unit MUST be installed vertically.
2.3
The unit must be positioned on a level surface.
2.4
Enough space should be left around the unit for pipe connections and for access
to controls and any safety valves fitted. Refer to Diagram 1 and the Dimensions
Table to determine a suitable position for the water cylinder.
2.5
NOTE: Ensure the floor can support the full weight of the unit (see TECHNICAL
SPECIFICATIONS).
2.6
DO NOT install where the unit may freeze.
2.7
The mains water supply to the property will be supplying both the hot and cold
water requirements simultaneously. It is recommended that the maximum water
demand is assessed and the water supply checked to ensure this demand can
be satisfactorily met.
NOTE: a high mains water pressure will not always guarantee high flow rates.
We suggest the minimum supply requirements should be 0.1 MPa (1.0 bar)
pressure and 20 litres per minute flowrate. However, at these values outlet flow
rates may be poor if several outlets are used simultaneously. The higher the
available pressure and flow rate the better the system performance.
2.8
LIMITATIONS:
The water cylinder should not be used in association with any of the following:
Situations where maintenance is likely to be neglected or safety devices
tampered with.
INSTALLATION AND SERVICE MANUAL

Publicité

loading

Ce manuel est également adapté pour:

Hws-2101cshm3-eHws-3001cshm3-e