Dometic TEC 30D EV Notice D'utilisation page 23

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 53
TEC30D EV
Interval
Inspection/maintenance
➤ Change the oil (chapter "Changing the oil" on page 24).
In the first month
or after 50 hours
➤ Check and clean the air filter (chapter "Servicing the air filter" on
Every 3 months or
every 50 hours
➤ Change the oil (chapter "Changing the oil" on page 24).
Every 250 hours
➤ Clean the motor's cooling devices.
➤ Check the valves.
➤ Check if the screws are intact and firmly tightened.
➤ Replace the fuel filter (chapter "Changing the fuel filter" on
Every 500 hours
➤ Replace the air filter (chapter "Servicing the air filter" on page 25).
➤ Clean the oil filter.
Once a year
➤ Check the diesel oil supply lines.
or every
1000 hours
The following must be carried out by a HATZ authorised retailer or
Dometic skilled personnel:
➤ Check the fuel injection pump.
➤ Check the vibration damper.
10.2
Preparing maintenance work
!
CAUTION!
Note the following for all maintenance work:
• The generator must not be running.
• All the parts must be cooled down.
➤ Open the generator cover (fig. 4 2, page 5).
➤ Switch the generator to no function with the main switch (fig. 4 1, page 5).
10.3
Finishing maintenance work
➤ Switch the generator to standby with the main switch (fig. 4 1, page 5).
➤ Close the generator cover (fig. 4 2, page 5).
EN