Télécharger Imprimer la page

Eaton Pulsar Série Guide Rapide page 5

Masquer les pouces Voir aussi pour Pulsar Série:

Publicité

UPS power
Nominal input voltage
Input frequency
Voltage/frequency of battery backup
outlets 6 in battery mode
Total output current for the 4 outlets
Output current of battery backup outlets 6
Leakage current
Input protection
Transfer time
Telephone surge protection
Sealed lead-acid battery
Automatic battery test
Average battery life
Operating temperature
Storage temperature
Operating relative humidity
Operating elevation
Safety standards
Electromagnetic compatibility standards
Warranty
MAU-00049 AC
Ellipse ASR 450
450 VA / 250 W
184 V - 264 V
50/60 Hz
230 V (50/60 Hz ± 1 Hz)
with pseudosinusoidal wave
5 A max
2 A max
0.03 mA
5 A resettable circuit breaker
5 ms typical
Tel, ISDN, ADSL, Ethernet
12 V, 4.5 Ah
Once a week
4 years typical, depending on number
of discharge cycles and temperature
0 to 35°C
-25°C to +55°C
0 to 85%
0 to 2000 m
IEC 60950-1, IEC 62040-1-1, CE certified
IEC 62040-2
2 years
5

Publicité

loading

Ce manuel est également adapté pour:

Pulsar ellipse asr 450