MODE CONVERSION OF THE HORIZONTAL RIGHTWARD (HR) AND LEFTWARD (HL)
TURNING INCREMENT
Standardly the horizontal angle mode is clockwise (display indication HR).
Press R/L to transform the horizontal angle mode to anti-clockwise (display indication HL).
The key R/L is of no effect to the vertical angle.
Press R/L again to transform the mode from HL to HR.
HORIZONTAL ANGLE LOCKED - UNLOCKED (HOLD)
·
Press HOLD; the horizontal angle reading will flash.
·
Keep HOLD pressed for 3 seconds.
·
Now the horizontal angle reading is locked and the reading stops flashing.
·
Press HOLD again to quit this mode / release the value.
SLOPE PERCENT MODE (%)
·
Press V/% to switch the vertical angular reading shown in degrees into percent reading.
·
The maximum % value will be 99.999 %; exceeding this the display will show ---,---- %
ANGULAR REPEATED MEASUREMENT
·
Press SFT + REP to start this mode.
·
T1 will flash in the display.
·
Aim at the first target and press 0SET; the horizontal reading will set to 0.
·
T2 will flash in the display.
·
Aim at the second target and press HOLD; display line 2 will show the average of the horizontal
readings, display line 1 will show the number of repeated measurements.
·
T1 will flash in the display; now you can aim again at the first target and all following steps can be
repeated as above.
·
Press SFT to quit this mode.
EN
21