120/240 Volt AC, 30 Amp Locking
Receptacle
Use a NEMA L14-30 plug with this receptacle. Connect a
4-wire cord set rated for 250 Volts at 30 Amps (or greater)
(Figure 10).You can use the same 4-wire cord if you plan to
run a 120 Volt load.
Figure 10 — 120/240 Volt AC, 30 Amp Receptacle
4-Wire Cord Set
Y (Hot)
NEMA L14-30
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 3,500 watts of power at
29.2 Amps for 120 Volts; 7,000 watts of power (7.0 kW) at
29.2 Amps for 240 Volts.The outlet is protected by a
double pole circuit breaker.
7000EXL Extended Life Generator
240V
120V
120V
W (Neutral)
X (Hot)
Ground (Green)
120 Volt AC, 30 Amp Locking
Receptacle
Use a NEMA L5-30 plug with this receptacle. Connect a
3-wire cord set rated for 125 Volts AC at 30 Amps to the
plug (Figure 11).
Figure 11 — 120 Volt AC, 30 Amp, Locking Receptacle
3-Wire Cord Set
Use this receptacle to operate 120 Volt AC, 60 Hz, single
phase loads requiring up to 3,600 watts (3.6 kW) of power
at 30 Amps.The outlet is protected by a double pole circuit
breaker and a 30 Amp push-to-reset circuit breaker.
12 Volt DC, 10 Amp Receptacle
This receptacle allows you to recharge a 12 Volt
automotive or utility style storage battery with the battery
charge cables provided (Figure 12).
Figure 12 — 12 Volt DC, 10 Amp Receptacle
This receptacle can not recharge 6 Volt batteries and can
not be used to crank an engine having a discharged battery.
See the section "Charging a Battery" (page 10) before
attempting to recharge a battery.