Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6. Run the compressor for 20 minutes. Make sure the globe valve is open and
there is minimal air pressure build-up in tank.
7. Check all air line fittings and connections/piping for air leaks by applying a
soap solution. Correct if necessary. NOTE: Minor leaks can cause the air
compressor to overwork, resulting in premature breakdown or inadequate
performance.
8. Check for excessive vibration. Readjust or shim air compressor feet, if nec-
essary.
9. After 20 minutes, close the globe valve. The air receiver will fill to "cut-out"
pressure and the motor will stop.
Before Each Start-Up:
1.
Place On/Auto/Off lever to "Off".
2.
Close the globe valve.
3.
Attach hose and accessories. NOTE: A regulator MUST be installed when
using accessories rated at less than 175 PSI.
NOTE: The hose or accessory will require a quick connect plug if the air outlet
is equipped with a quick connect socket.
Risk of Bursting. Too much air pressure causes a hazard-
ous risk of bursting. Check the manufacturer's maximum
pressure rating for air tools and accessories. The regulator outlet pressure
must never exceed.

How to Start:

1.
Turn the On/Auto/Off lever to "On/Auto" and allow tank pressure to build.
Motor will stop when tank pressure reaches "cut-out" pressure.
2.
When the tank pressure reaches "cut-out" pressure open the globe valve.
IMPORTANT: When using regulator and other accessories refer to the manufac-
turers instructions.
The compressor is ready for use.
15-ENG
A18791

Publicité

Table des Matières
loading

Table des Matières