In any operation mode, the safety devices causes the following effects :
Photo-cell - Jumper JP2 not inserted : This device has effect only during the closure phase or in the pause period. If an obstacle covers the
photo-cell during the closure phase, the gate stops and reverses its motion after approx. 1,5 sec. If an obstacle covers the photo-cell during the pause
period this last one is reset and the automatic closure is therefore delayed.
Photostop - Jumper JP2 inserted : If an obstacle covers the photo-cell during the gate's motion (opening or closure), or during the period preceding
the operating cycle's start, then the gate is temporarily stopped, until the obstacle is not removed. The blinker will light with a fixed light to signal the
irregular condition. When the obstacle is removed and the photocell is freed, an opening cycle will start. If an obstacle covers the photostop during the
pause period this last one is reset and the automatic closure is therefore delayed.
F) Electrical and mechanical characteristics
Dimensions of electronic card : 100 x 105 x 45 mm
Weight of electronic card : 0,55 Kg
Mains power supply : 230Vac +/- 10%
Stand-by power consumption : approx. 0,5 W
Operating temperature range : 0 to + 60 °C
Single-phase motor power supply : 230Vac 1 HP max
Blinker power supply : 230Vac 40 W max
Accessories power supply : 24Vac 2 W max
Motor's work time : programmable, 1 to 120 sec.
Pause time : programmable, 1 to 250 sec.
Caution : The unit must be not switched on if the connected loads or the power supply exceed the a.m. limits. Failure to observe this precaution can
result in damage to persons, animals or objects for which the manufacturer cannot be held responsible.
G) Electric connections
5 electric connectors are fitted to the card :
a)
J1 5-pole Terminal board for the connection of the devices operating with 230Vac mains power supply (motor, blinker)
b)
J2 4-pole connector for the optional connection of a power regulator card
c)
J3 2-pole Terminal board for the connection of the aerial cable
d)
J4 8-pole Terminal board for the connection of the devices operating at low voltage (commands, safety devices, 24Vac power supply)
e)
J5 2-pole Terminal board for the connection of the 230Vac mains power cable